Selasa, 20 April 2021

081362449440 Jual Water Quality Meter ISTEK Distributor Indonesia EC/TDS/Salinity/Temp Type : EC 40 N K4000EC EC 400L EC 470L DO 30N EC 40 N Harga pH Meter DO Meter Conductivity Meter ORP EC Rp...

 BINTANG INSTRUMENT 

HP       : 081362449440 / 081310157965 

Email  : b081362449440@yahoo.com

Up       : Mr Jonathan

 


====================================
====================================

 1. Benchtop Water  Quality Meter :

    Conductivity TDS Salinity Resistivity Temp.

     Type : K4000EC

 

Specification : 

Measuring Item


K4000-EC
(1 CH)

Conductivity

 Range

 0.0 ~ 199,999  uS/cm

 Resolution

 0.01 / 0.1

 Accuracy

 ±0.5 %

TDS

 Range

 0 ~ 1999 mg/l

 Resolution

1

 Accuracy

 ±2 %

Salinity

 Range

 0 ~ 80 ppt

 Resolution

 0.001 / 0.01 / 0.1

 Accuracy

 ±0.5 %

Resistivity

 Range

 5Ω x cm ~  100 MΩ x cm

Temp.

 Range

 -10 ~ 110 ℃

 Resolution

0.1

 Accuracy

 ±0.4 ℃

 Temperature

compensation

 Automatical Temperature compensation

 Type

 PT100 / 1000  / NTC

 

Conductivity/TDS/Salinity/Resistivity/Temp Meter K4000-EC

 

* Conductivity/TDS/Salinity/Resistivity/Temp
4.3" full Color LCD
* Simultaneous display of Conductivity and Temp.

* Resistivity valu display
* Built in Printer (Optional)
* Data to Excel via SMSD program
 


Feature :

- 5 Years Quality Assurance  except consumables
-  4.3 TFT Full color LCD
- Internal Printer(Optional) installation available

-​ Data to PC via SMSD program.(Data in Excel from available)

-  Measuring Item: Conductivity/TDS/Salinity/Resistivity/Temp.

- Resistivity value() displayed 

- Data to PC via SMSD program

- Two Way RS232C Communications
- RS232C Interface provided  

 ========================================================================

 ========================================================================

 

2. Benchtop  Water  Quality Meter :

      Parameter : Cond Salt Temperature

     Type : EC 400L

Conductivity

  Range

 0 to 199,999μS/cm

  Resolution

 0.01 / 0.1

  Relative Accuracy

 ±0.5%

  Salinity

  Range

 0.0 to 80ppt

  Resolution

 0.1

  Relative Accuracy

 ±0.1

Temperature

  Range

 -10 to 110℃

  Resolution

 0.1℃

  Relative Accuracy

 ±0.4℃

  Temperature Compensation

 Auto

  Calibration

 Auto

  Datalog

 내장 100 Point

  Print Capability

   Yes

  Display

   Custom LCD

  Inputs

   BNC, ATC, Power, RS232C

 Outputs

   Recorder, RS232C (Computer / Printer)

 Power

   AC/DC Power Adaptor

  Certification

ISO9001, CE mark

 Dimension

200(L) x 260(W) x 90(H), Weight 0.96kg

 

 ========================================================================

 ========================================================================

3. Benchtop Water Quality Meter 

   Parameter : Cond , TDS, Salt, Temperature

   Type : EC-470

 Conductivity

 Range

 0 to 199,999μS/cm

 Resolution

 0.01 / 0.1 (Auto)

 Relative Accuracy

 ±0.5%

 TDS

 Range

 0 to 1,999mg/L

 Resolution

 1mg/L

 Relative Accuracy

 ±2%

 Salinity

 Range

 0.0 to 80.0ppt

 Resolution

 0.1

 Relative Accuracy

 ±0.1

 Temperature

 Range

 -10 to 110

 Resolution

 0.1

 Relative Accuracy

 ±0.4

 Resistivity

 5Ω * cm to 100MΩ * cm

 Temperature Compensation

 Auto

 Calibration

 Auto

 Datalog

 500 Points

 Print Capability

 Yes

 Display

 Color Graphic LCD

 Inputs

 BNC, ATC, Power, RS232C

 Outputs

 RS232C (Computer / Printer)

 Power

 AC/DC Power Adaptor

 Certification

 ISO9001, CE mark

 Dimension

 200(L) x 260(W) x 90(H), Weight 0.96kg

 

 
pH/ISE Meter

DO Meter

Conductivity Meter

Multi Meter

MLSS/Turbidity/Residual Chlorine

B.O.D Incubator

On-line Analyzer

Controllers

COD Analyzer

Electrode/Accessory

pH/DO/EC Electrode

ISE Electrode

Accessories






 ========================================================================

 ========================================================================

4. DO Meter DO-30N DO/O₂/Air (ISTEK)

  Type DO -30N

Brochure Link : 

Brochure DO Meter DO-30N PDF Bintang Instrument . 


 

DO-30N

 

Introduction
DO -30 N is a portable DO meter that can measure DO, O2, air, and temperature simultaneously. This can easily be operated.


Features
-Wide and vivid custom LCD
-Waterproof (IP66) housing
-Fast, accurate, and easy to use / RS232C Communication
-Simultaneous display of DO (O2 and air), temperature, and current time
-Automatic temperature compensation
-Automatic compensation for salinity and barometric pressure
-Uses high sensitive polarographic-type DO sensor
-Self diagnostics / low battery alarm / rechargeable battery
-Fitted with a supporter in a laboratory


Specification :


MODEL



DO-30N



DO



Range



Resolution



Relative Accuracy



0.00 to 19.99 mg/L



0.01/0.1

 ========================================================================

 ========================================================================

5. EC/TDS/Salinity/Temp

   Type : EC 40 N 

ISTEK - EC-40N - TRIDINAMIKA

Specification

Conductivity Range 0 to 199,999μS/cm
Resolution 0.01 / 0.1
Relative Accuracy ±0.5%
TDS Range 0 to 1999mg/
Resolution 1mg/L
Relative Accuracy ±0.2%
Salinity  Range 0.0 to 80.0ppt
Resolution 0.1
 Relative Accuracy ±0.1
Temperature Range -10 to 110℃
 Resolution 0.1℃
 Relative Accuracy ±0.1℃
Temperature Compensation Auto
Calibration Auto
Datalog 100 Points
Print Capability Yes
Display Backlight LCD
Inputs BNC, 8PIN(ATC), 7.5V Adaptor
Outputs RS232C (Computer / Printer)
Power Rechargeable Battery/ DC Power Adaptor
 Certification  ISO9001, CE, GD mark
Dimension  220(L) x 80(W) x 40(H), Weight 0.45kg
Waterproof IP66

ISTEK – EC-40N Feature

  • Extremely short response time and easy-to use
  • Clear Custom LCD illuminated
  • Two-way RS232C communication
  • 100 Points Internal Data-log
  • A waterproof housing & Device self-test
  • Automatic/Manual Calibration for convenient use
  • Precise Measurement with Cell constant Designation
  • Automatic Range Selection for current Data Display
  • Simultaneously Display of Conductivity(or Salinity), temp and current time

Accessory

(1) Standard
– Conductivity Cell(K=1.0) / ATC Probe
– Conductivity Standard Solution(1413μS/cm)125ml
– Instruction Manual
– Rechargeable Battery /DC Adaptor


(2) Option
– Conductivity Cell/ATC Probe(K=1.0, K=0.1, K=0.01, K=10)
– Conductivity Standard Solution
– RS232C Interface Cable
– Exterior Thermal Printer
– Carrying Case




























.

.

.

..



      

Tidak ada komentar: