081362449440 Jual Spectrophotometer CE7410 , CE2021 CECIL INSTRUMENT , CECIL INSTRUMENT INDONESIA DISTRIBUTOR , DISTRIBUTOR CECIL INSTRUMENT INDONESIA , Spectrophoto meter Cecil CE 2021 , Spectrophoto meter Cecil CE 3021 , Jual Spectrophoto meter Cecil CE 2021 Indonesia , Spectrophoto meter Cecil CE 3021 Indonesia ,

BINTANG INSTRUMENT 

HP : 081362449440 / 081310157965 
Email : b081362449440@yahoo.com
Up : Mr Jonathan
===============================









































































































































































Spectrophotometer
Type : CE7410
Brand : CECIL INSTRUMENT









===============================
UV VIS Spectrophoto meter
Type : CE2021
Brand : CECIL INSTRUMENT

SPECIFICATION :
Product Overview
B13702 Cecil CE 2021 UV VIS spectrophotometer
Accomodates 100mm cells
Overall dimensions: 195 x 480 x 430mm HxWxD
Optical band width: 5nm
Wavelength range: 190 - 1000nm
Up to 30 methods and curves stored
Keyboard control
LCD display - dim screen
110 - 250V, 50/60hz, 170W
Cream coloured moulded plastic
RS232C and parallel ports
Average condition
Serial No. 123433











.
..
.

===============================


UV VIS Spectrophoto meter
Type : CE3021
Brand : CECIL INSTRUMENT

SPECIFICATION :




.
.
.
..
.

===============================
AutoQuest Liquid Chromatography Autosampler
Type : CE4800
Brand : CECIL INSTRUMENT


Specification : Available in 50 or 100 sample position versions, these astoundingly reliable AutoQuest autosamplers provide for ultra low carryover, ultra high injection precision, priority sampling, replicate injections and sample volumes from 10 µL to 2 mL.

With ultra low carry-over
Ultra low carry-over. 50 or 100 sample position versions. Analytical LC. 
  • Catalog NumberCE 4800-100
  • QuantityEA
  • Number of Samples50 or 100 Samples
  • pH RangeN/A
  • Injection Volume Range10 uL to 2 mL.
  • Injection MethodFull Loop
 ===================================


CECIL INSTRUMENT INDONESIA , DISTRIBUTOR CECIL INSTRUMENT INDONESIA , CECIL INSTRUMENT INDONESIA , AGEN PENJUAL CECIL INSTRUMENT DI INDONNESIA

SPECIFICATION UV VIS SPECTROPHOTOMETER CE7410

SPECIFICATION UV VIS SPECTROPHOTOMETER CE2021

SPECIFICATION UV VIS SPECTROPHOTOMETER CE3021 

AutoQuest Liquid Chromatography Autosampler CE7410

SPECIFICATION UV VIS SPECTROPHOTOMETER CE7410
INDONESIA

SPECIFICATION UV VIS SPECTROPHOTOMETER CE2021
INDONESIA

SPECIFICATION UV VIS SPECTROPHOTOMETER CE3021 
INDONESIA

AutoQuest Liquid Chromatography Autosampler CE7410
INDONESIA

Jual SPECIFICATION UV VIS SPECTROPHOTOMETER CE7410
INDONESIA

Jual SPECIFICATION UV VIS SPECTROPHOTOMETER CE2021
INDONESIA

Jual SPECIFICATION UV VIS SPECTROPHOTOMETER CE3021 
INDONESIA

Jual AutoQuest Liquid Chromatography Autosampler CE7410
INDONESIA

SPECIFICATION UV VIS SPECTROPHOTOMETER CE7410 PDF

SPECIFICATION UV VIS SPECTROPHOTOMETER CE2021 PDF

SPECIFICATION UV VIS SPECTROPHOTOMETER CE3021 PDF

Jual AutoQuest Liquid Chromatography Autosampler CE7410
INDONESIA PDF

 
Aurius and Super Aurius Spectrophotometers
Purchased Spectrophotometers are supplied complete with single cell holder, power cable, operators manual and short form instructions.
Specifications and Ordering of spectrophotometers and accessories
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specifications without notice.
Monochromator
Optical Bandwidth
Wavelength Range
Wavelength Accuracy
Wavelength Reproducibility
Self Test and Calibration
Straylight
Display Screen - LCD
Display Scrolling
Autozero
Photometric Ranges
Photometric Accuracy
Photometric Noise
Stability
Multi-Wavelength Analysis
Assay Program  
Curve Fitting and Editing
Cell and Wavelength Programming
Method Storage
Absorbance Ratios
Peak Seek
Reaction Kinetics
Batch Sampling
Real Time Clock
Computer/printer interfaces
Sample Temperature
Size
Weight
Power Requirements
Littrow using 1200 L/mm holographic grating
4nm
190-1100nm; 325-1100nm visible versions
Better than ±1nm
0.1nm
Automatic at switch on
Typically less than 0.01% at 220nm and 340nm
High resolution backlit with contrast control  
Provides 6 screen widths for viewing plots etc.
Automatic by press button
Digital display of -0.3-3A, 0-200%T, 0-9999C
±0.005A or 1% whichever is greater
Less than ±0.0002A (500nm)
Better than 0.001A/hour at constant temperature
2 and 3 wavelength methods.
Enter multi-wavelength formula for automatic computation and formatting of any assay
Linear, quadratic or cubic; up to 30 standards
Up to 8 cells and 10 wavelengths combined
Up to 30 methods stored in protected memory
260/280nm or two selected wavelengths
Automatic search programme, baseline corrected
Tabulation of results, reaction plots, reprocessing
100 samples, internal control, screen display
Timed and dated reports
Bi-directional serial RS232 and USB ports
Displayed and set from keyboard
480 x 340 x 205mm
16.8Kg Visible; 18.6Kg UV; + 0.9Kg with printer
110-250V, 50/60Hz, 170W/120W UV/Visible versions
Super Aurius additional specifications:-
Optical Bandwidth
Wavelength Scale Expansion
Scan Speed
Photometric Plotting Ranges
Baseline Flatness
Overlayed Spectra
Spectral Reprocessing
Spectral Storage
Derivative Spectra
Time Course Plotting
1.8nm
Selectable by keyboard entry 1-100nm/cm
Selectable by keyboard entry 1-4000nm/m
Keyboard entry of limits; or automatic optimum  
Better than ±0.002A (300nm/min) most of range
Spectra and derivatives with or without offset
Spectra manipulated and replotted over any range
Up to 100 spectra may be stored security code protected
1st and 2nd derivatives
Plots may be reprocessed and stored
Aurius Visible Range
CE 2011 Spectrophotometer
325-1100nm Wavelength range
4nm Bandpass

CE 2031 Spectrophotometer
325-1100nm Wavelength range
4nm Bandpass. With Integral Printer

UV / Visible Range

CE 2021 Spectrophotometer
190-1100nm Wavelength range
4nm Bandpass

CE 2041 Spectrophotometer
190-1100nm Wavelength range
4nm Bandpass. With Integral Printer

CE 2021D and CE 2041D Tablet Dissolution Spectrophotometers
Special version suitable for tablet dissolution applications, using TD software

System 1
Spectrophotometer, spare lamp(s) spare fuses, 2 cells and dust cover.
Super Aurius
CE 3021 Spectrophotometer
1.8nm Bandpass, 190-1100nm wavelength range, scanning.

CE 3041 Spectrophotometer
1.8nm Bandpass, 190-1100nm wavelength range, scanning. With integral printer.

CE 3021D and CE 3041D Tablet Dissolution Spectrophotometers
Special versions suitable for tablet dissolution applications, using TD software.

System 1 : Cells and Spares
Spectrophotometer with two silica cells, spare lamps, spare fuses and dust cover.
Example: CE 2021 system 1 is a CE 2021 with spare deuterium and tungsten lamps, spare fuses, 2 silica cells and dust cover.
Cell Holders
Adjustable holder for sipette or single 10mm cell
Universal cell holder, 10mm cells upwards
Long pathlength cylindrical cell holder
Holder for solid samples or films
Ultra-microcell holder : 50-µl cells
Ultra-microcell holder : 5 and 10-µl cells

Cell Changers And Holders
4 cell automatic changer (no holder)
4 x 10mm cell holder for auto changer
4 x 50mm cell holder for auto changer
6 cell automatic changer and holder
8 cell tablet dissolution autochanger system
4 microcell manual changer and holder
3 x cell changer (1-40mm) for water analysis

Sipette And Batch Sampling
Holder for SIP or sipette cells up to 50mm
Batch sampler for 40 samples with pump
Batch sampler for 100 samples with pump
Return micro-sipette system no cell or holder

Calibration Filters
Holmium filter in holder
Didymium filter in holder
Set of 2 certified wavelength filters in holders
Set of 4 certified absorbance filters in holders
Set of 6 certified absorbance filters in holders

Temperature Control - Water
Holder for single or sipette cell
Holder for 4 cells - for autochanger
Lid and pipe port for water thermostatting

Temperature Control - Thermoelectric
Thermoelectric programme controller
Holder for single or sipette cell
Holder for 4 cells with autochanger

Temperature Programming
Thermoelectric programme controller
Single 10mm cell holder

Sample Stirring
Electronic controller for sample stirring
Cell holder for sample stirring
Water thermostatted holder for stirring
4 cell holder for sample stirring

Lamps
Deuterium lamp with hours indicator
Tungsten halide lamp - in pairs

Printers And Cables
RS232c cable for 25 pin PC  
RS232c cable for 9 pin PC  
Printer connection cable
Dot matrix printer
Print rolls and ribbon for integral printer
Part No.
1010 32 00
1010 38 00
1010 39 00
2020 33 00
2020 39 00
2021 30 00


2021 34 00
2010 24 00
2010 36 00
2021 36 00
3021 37 00
2020 38 00
2020 35 00


2020 37 00
2021 82 00
2021 82 02
2021 21 00


202 01 44
303 01 30
303 40 00
594 44 00
594 66 00


1010 33 00
2020 36 15
1010 05 00


CE 2024
2020 31 20
2021 32 20


CE 2024
2020 31 20


7200 31 01
2010 32 00
2010 33 00
2010 34 00


2202 01 42
2303 01 40


2021 26 00
2021 83 00
8000 71 00
8000 70 01
2020 03 20

Some Examples of Software:-

Assay Program
Construction and entry of mathematical formulae involving measurements at multiple wavelengths with automatic computation of assay results.

DataStream
Fast data transfer to PC for use with Excel or other spread sheets.

Quant M
Multi wavelength assays at 2 or 3 wavelengths, Warburg and Christian assays at 2 or 3 wavelengths, wine assay, at up to 10 wavelengths.

ColourScan
The instrument will automatically perform a wavelength scan and perform a variety of numerical analyses of colour.

Quant P
Protein assay using the methods of Lowry, Bradford, Biuret and BCA.

Quant S - Super Aurius only
Quantitation of corrected bands, difference spectra, spectral stripping, overlayed spectra, spectral storage.

Program C
Cell program for up to 4, 6 or 8 cells.

Program W
Wavelength program for up to 10 wavelengths and timed interval measurements at a fixed wavelength.

Scan - Aurius only
Wavelength scans with peak labelling and peak tables. Time course plots while re-processing.

Kinetics
Kinetic measurements with plots, reprocessing of data.

Kinetics M
Multi-cell Kinetics linked with autocell changing, and plotting of reaction curves.

Validation
Absorbance and Wavelength validation using certified standards or liquids. Validation of optical bandwidth, etc.

 