Specification :
Video :
============================================================
portable octane analyzer is the latest development of a new generation of portable high-precision octane detector. The product can quickly detect gasoline, diesel label. It has the characteristics of small volume, simple operation, good repeatability, fast detection speed and can be widely used in petrochemical companies, petrochemical enterprises, oil depots, gas stations and other national quality inspection and inspection departments.
Features:
1 small size
2 is simple
3 good reproducibility
4 detection speed
Technical Parameters:
Working temperature: -15 ℃ ~ +55 ℃
Measurement time: 1 ~ 5s
Repeat error: ± 0.2
Host weight: 0.9kg
Power: DC 6V
Host size: 230 × 295 × 115mm
============================================================
BI-131 gasoline octane tester is the latest generation of instruments, mining the international advanced measurement principle, according to the domestic oil variety design and development, to fill a variety of oil detection gaps, with accurate and rapid detection of oil Octane number and cetane number, two languages in Chinese and English digital display, large-capacity storage of data and can directly print the measured value, the page design user-friendly operation is simple, the use of imported shell and chip, LAB131 octane hexadecane The value of the sensor using the metal metal sealed design, long standby cycle charge, suitable for work site, field, laboratory operations.
Features:
1.BI-131 octane number cetane analyzer can simultaneously detect gasoline octane number and diesel cetane number, a machine dual-use.
2.BI-131 octane number cetane number analyzer through long-term data collection, database integrity, into the new technology to develop a variety of detection modes, can detect vehicle gasoline, ethanol gasoline, high octane oil, low octane oil Product, methanol gasoline (methanol gasoline only provide reference value), national standard diesel, reconcile diesel, catalytic diesel, biodiesel, and other oil, fill the oil octane number and cetane number detection gap.
3. The introduction of international dielectric constant measurement principle, according to the Chinese market demand for design and development, is a fully in line with the domestic market instruments, and include the original domestic testing equipment advantages.
4. Detection of fast, accurate and simple operation, large-screen Chinese display, with EL backlight support, easy to use in the dimly lit environment, the host panel Chinese menu operation.
5. The original imported instrument shell, durable, and small and easy to carry, the chip and the core components are imported, increase the instrument sensitivity and service life, the circuit board can be three years warranty, the company promised three years of any non-human quality problems, Free replacement. Sensor alloy metal sealed manufacturing, packaging box with high strength, high impact resistance, absolutely sealed waterproof, moisture, dust, with a grid sponge.
6. Can be pre-set mode, the lower limit, out of range automatically display, user-friendly needs.
7. With automatic shutdown energy-saving features, low-power design, 4 rechargeable batteries, can be recycled charging, battery reliability more.
Technical indicators:
Octane number of measurement range (ON): 40-120
The allowable measurement error of the octane meter: ± 0.5
The octadic meter can be measured by the floating range: ± 0.2
Measurement range of cetane number (CN): 20-100
The allowable measurement error of the cetane number meter: ± 1
The floating range of the measurement results of the cetane number is ± 0.5
Measurement time (seconds): <20
The battery voltage is too low the critical value of V: 2.5
Host, mm (length × width × height): 224x106x40
Sensor mm: 60х100
Weight Kg (max): 5
Continuous use time (hours): 15
Output: LCD display, print output
Current consumption: 30ma
===============================================================
==================================================================
===============================================================
=================================================================
Introduction:
BI130 is a portable, all-digital gasoline octane number tester that can be quickly and easily, accurately, without damaging the octane number of the gasoline sample and the cetane number of the diesel, both for the laboratory , Can also be used for field testing. It is the first domestic can detect gasoline octane number, also applies to diesel cetane instrument. It uses the dielectric constant method to detect octane number and cetane number detection technology, in full compliance with international standards (ASTM D2699-86, ASTM D2700-86), commonly used in the analysis of power gasoline and diesel quality, with the research method RON, motor The method MON corresponds to the cetane number CN.
Features:
1 Measure gasoline octane number and diesel cetane number
2 with the most authoritative domestic gasoline octane number and diesel cetane number database
3 repeatable error range is 0.2 octane units
4 A variety of additives containing gasoline can be measured
5 also shows RON, MON and anti-blast index (AKI).
6 measurement of diesel cetane number CN, diesel type
7 powerful processing chip can be fast and accurate data processing
8 The instrument is equipped with six oil test data models to suit the various conditions of the oil measurement
9 easy to operate, small size, easy to carry, box anti-vibration, anti-solvent, sealed, the use of low cost
10 through the RS232 data transmission line can be connected to the computer, the computer can be directly operated and printed
11 Traditional octane number test machine and cetane number testing machine need professional and technical personnel operation, the process is cumbersome, and need to consume a large number of reference fuel, equipment maintenance costs are expensive, so that ordinary users to determine the octane number of cetane There is a lot of difficulty. The rapid measurement of fuel for Lab130 is more efficient than traditional methods.
Technical Parameters:
Measurement items: all kinds of gasoline, diesel
Octane measurements are met: ASTM D2699-86, ASTM D2700-86.
Diesel cetane measurements are met: ASTM D4737-03, ASTM D613, EN ISO 5165.
Measuring range: octane number: 40-120 (accuracy ± 0.5), cetane number: 20-100 (accuracy ± 1)
Measurement time for each sample: <8 seconds
Instrument consumption current: 30mA,
Battery standby time: 100 hours
Operating range: temperature -10 ℃ ~ +40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106kPa
Dimensions
Sensor: 60mm × 100mm,
Host: 236mmx130mmx43mm
=================================================================
Portable gasoline octane diesel cetane number (referred to as gasoline and diesel dual-use) detector, is used for mechanized forces, oil refining enterprises, oil storage and oil unit rapid determination: aviation gasoline, gasoline, gasoline , Ethanol gasoline and methanol gasoline octane number, diesel cetane number and cetane index (calculation method) hand-held special pocket instrument. The instrument uses a small, user-friendly design, with a simple operation, easy to carry, the determination of fast, high precision, wide range, full-featured features.
Features:
1 • Sensor signal using digital transmission technology, anti-interference ability, small variation, high precision: reproducibility, repeatability is very good.
2 • The calibration procedure of the instrument is automatic assignment calibration, the rigorous mathematical model, the determination of the operation can be automatically assigned calibration, the program is simple, scientific method, accurate and reliable. Customers can do their own maintenance calibration, to facilitate customers.
3 • Automatic return of the measurement program is based on the rigorous mathematical model, with advanced electronic measurement technology as a means (high-precision sensor), ASTM-CFR test machine as a standard, targeted regression, targeted , And the measurement accuracy and the measurement range were improved.
4) The development of the above procedures can be done by a key test, the instrument has passed the pre-return, the national standard gasoline, aviation gasoline, vehicle diesel to achieve a key determination (referred to as a push), screen display research, motor and anti- Burst index (referred to as a screen three).
.
.
.
.
.
.
HP :
081362449440 / 081310157965
Email
: b081362449440@yahoo.com
Up :
Mr Jonathan
===============================
===============================
PORTABLE OKTAN METER
Type : Oktis 2
Fungsi : Alat Ukur Oktan pada Bahan Bakar Bensin
Specification :
Range of
measured octane
levels
|
70 to 110
|
Minimum
quantity of gas required for octane number determination in continuous-flow
mode
|
2 - 5 l
|
Time
required to prepare the meter for operation, sec
Minimum quantity
of gas required for octane number determination in sensor immersion
mode
|
not more
than 15
80 ml
|
Power
supply voltage (two AA
batteries)
|
3V
|
Consumed
current
|
not
exceeding 100 mА
|
Operating
conditions:
-
temperature of checked gasoline
-
incumbent temperature
- humidity
at 30°С, %
|
0°С to +50°С
-10°С to +40°С
30 to 80
|
Mass
|
not
exceeding 0,36 kg
|
Complete Unit :
• Carton
1
pc
• Octane
number
meter
1 pc
• User
manual
1 pc
•
Instructions on the removal of
deposits
1 pc
• Set of
spare
seals
1 pc
•
Case
1 pc
• AA
Battery
2 pcs
1 –
electrical compartment
2 –
transition compartment with seal rings
3 – metering
tube
4 – digital
display
5 – ON/OFF
button
6 - cover
7 – gasoline
level mark
8 –
correction and mode switchover button
9 – calibration button (no access)
081362449440 Jual Oktis-2 OCTANE NUMBER Tester meter Portabable OKTIS-2 Jual Alat Uji Octane Number Meter Portabable Oktis-2 Jual Beli OKTIS-2 ANALYZER METER OCTANE NUMBER portable fuel octane number analyzer tester meter oktis-2! new! price USD
Video :
Foto :
Video :
============================================================
1) Portable Octane Analyzer
Model : BI-THY-XWA
introduction:portable octane analyzer is the latest development of a new generation of portable high-precision octane detector. The product can quickly detect gasoline, diesel label. It has the characteristics of small volume, simple operation, good repeatability, fast detection speed and can be widely used in petrochemical companies, petrochemical enterprises, oil depots, gas stations and other national quality inspection and inspection departments.
Features:
1 small size
2 is simple
3 good reproducibility
4 detection speed
Technical Parameters:
Working temperature: -15 ℃ ~ +55 ℃
Measurement time: 1 ~ 5s
Repeat error: ± 0.2
Host weight: 0.9kg
Power: DC 6V
Host size: 230 × 295 × 115mm
============================================================
2) Gasoline octane tester
Model : BI-131
Introduction:BI-131 gasoline octane tester is the latest generation of instruments, mining the international advanced measurement principle, according to the domestic oil variety design and development, to fill a variety of oil detection gaps, with accurate and rapid detection of oil Octane number and cetane number, two languages in Chinese and English digital display, large-capacity storage of data and can directly print the measured value, the page design user-friendly operation is simple, the use of imported shell and chip, LAB131 octane hexadecane The value of the sensor using the metal metal sealed design, long standby cycle charge, suitable for work site, field, laboratory operations.
Features:
1.BI-131 octane number cetane analyzer can simultaneously detect gasoline octane number and diesel cetane number, a machine dual-use.
2.BI-131 octane number cetane number analyzer through long-term data collection, database integrity, into the new technology to develop a variety of detection modes, can detect vehicle gasoline, ethanol gasoline, high octane oil, low octane oil Product, methanol gasoline (methanol gasoline only provide reference value), national standard diesel, reconcile diesel, catalytic diesel, biodiesel, and other oil, fill the oil octane number and cetane number detection gap.
3. The introduction of international dielectric constant measurement principle, according to the Chinese market demand for design and development, is a fully in line with the domestic market instruments, and include the original domestic testing equipment advantages.
4. Detection of fast, accurate and simple operation, large-screen Chinese display, with EL backlight support, easy to use in the dimly lit environment, the host panel Chinese menu operation.
5. The original imported instrument shell, durable, and small and easy to carry, the chip and the core components are imported, increase the instrument sensitivity and service life, the circuit board can be three years warranty, the company promised three years of any non-human quality problems, Free replacement. Sensor alloy metal sealed manufacturing, packaging box with high strength, high impact resistance, absolutely sealed waterproof, moisture, dust, with a grid sponge.
6. Can be pre-set mode, the lower limit, out of range automatically display, user-friendly needs.
7. With automatic shutdown energy-saving features, low-power design, 4 rechargeable batteries, can be recycled charging, battery reliability more.
Technical indicators:
Octane number of measurement range (ON): 40-120
The allowable measurement error of the octane meter: ± 0.5
The octadic meter can be measured by the floating range: ± 0.2
Measurement range of cetane number (CN): 20-100
The allowable measurement error of the cetane number meter: ± 1
The floating range of the measurement results of the cetane number is ± 0.5
Measurement time (seconds): <20
The battery voltage is too low the critical value of V: 2.5
Host, mm (length × width × height): 224x106x40
Sensor mm: 60х100
Weight Kg (max): 5
Continuous use time (hours): 15
Output: LCD display, print output
Current consumption: 30ma
===============================================================
3) Cetane number tester
Model : BI-132
Brief introduction:
BI-132 cetane number tester is a new generation of cetane number, adopt international advanced measuring principle, according to the diversity of domestic oil product design and development, fill the blank of the variety of oil testing and can with precise and rapid detection of oil cetane number, both Chinese and English two languages, the large capacity data storage and can print directly measured values, page design humanized operation is simple, adopts imported case and chips, sensors use alloy metal seal design, BI-132 cetane meter long standby, a charging circuit suitable for on-site, field and laboratory work.
Main features:
1.BI-132 can detect diesel cetane value.
2. After long-term data collection, the instrument has a complete database, and is integrated with new technology to develop a variety of detection modes, which can detect national standard diesel oil, blended diesel oil, catalytic diesel oil, biodiesel oil, and other oil products, and fill in the gaps in the detection of cetane number of these oil products.
3. The introduction of international dielectric constant measurement principle, according to the Chinese market demand design and development, is a fully in line with the domestic market of the instrument, and includes the advantages of the original domestic testing instrument.
4. Quick and accurate detection, simple operation, large screen Chinese display, EL backlight support, easy to use in dim light environment, host panel Chinese menu operation.
5. The original instrument shell imported from Germany is strong and durable, small and easy to carry. The chip and core components are imported from Germany, which increases the sensitivity and service life of the instrument.
Sensor metal alloy fully sealed manufacturing, packaging boxes.
6. The upper and lower limits of the mode can be set in advance, and the exceeded range will be displayed automatically for the convenience of user detection.
7. With automatic shutdown energy saving function, low power consumption design, 4 sections of rechargeable batteries, recyclable charging, battery reliability is stronger.
Principle of measurement:
The principle of BI132 cetane number tester is to measure the insulation magnetic conductivity and electromagnetic induction charge characteristics of diesel oil cetane number.
The results are obtained by measuring the dielectric properties of the oil and comparing them with the known in-memory data models.
The instrument is very sensitive and can detect tiny dielectric parameter changes, so as to detect petroleum product parameters such as cetane number.
Technical parameters:
Measuring items: all kinds of diesel
Diesel cetane number measurement in accordance with: ASTM d4737-03, ASTM D613, EN ISO 5165.
Measuring range: cetane number: 20-100 (accuracy 1)
Measurement time of each sample: < 20 seconds
Instrument consumption current: 30mA,
Battery operation time: 100 hours
Low operating range: temperature - 10 ℃ ~ + 40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106 kpa
BI-132 cetane number tester is a new generation of cetane number, adopt international advanced measuring principle, according to the diversity of domestic oil product design and development, fill the blank of the variety of oil testing and can with precise and rapid detection of oil cetane number, both Chinese and English two languages, the large capacity data storage and can print directly measured values, page design humanized operation is simple, adopts imported case and chips, sensors use alloy metal seal design, BI-132 cetane meter long standby, a charging circuit suitable for on-site, field and laboratory work.
Main features:
1.BI-132 can detect diesel cetane value.
2. After long-term data collection, the instrument has a complete database, and is integrated with new technology to develop a variety of detection modes, which can detect national standard diesel oil, blended diesel oil, catalytic diesel oil, biodiesel oil, and other oil products, and fill in the gaps in the detection of cetane number of these oil products.
3. The introduction of international dielectric constant measurement principle, according to the Chinese market demand design and development, is a fully in line with the domestic market of the instrument, and includes the advantages of the original domestic testing instrument.
4. Quick and accurate detection, simple operation, large screen Chinese display, EL backlight support, easy to use in dim light environment, host panel Chinese menu operation.
5. The original instrument shell imported from Germany is strong and durable, small and easy to carry. The chip and core components are imported from Germany, which increases the sensitivity and service life of the instrument.
Sensor metal alloy fully sealed manufacturing, packaging boxes.
6. The upper and lower limits of the mode can be set in advance, and the exceeded range will be displayed automatically for the convenience of user detection.
7. With automatic shutdown energy saving function, low power consumption design, 4 sections of rechargeable batteries, recyclable charging, battery reliability is stronger.
Principle of measurement:
The principle of BI132 cetane number tester is to measure the insulation magnetic conductivity and electromagnetic induction charge characteristics of diesel oil cetane number.
The results are obtained by measuring the dielectric properties of the oil and comparing them with the known in-memory data models.
The instrument is very sensitive and can detect tiny dielectric parameter changes, so as to detect petroleum product parameters such as cetane number.
Technical parameters:
Measuring items: all kinds of diesel
Diesel cetane number measurement in accordance with: ASTM d4737-03, ASTM D613, EN ISO 5165.
Measuring range: cetane number: 20-100 (accuracy 1)
Measurement time of each sample: < 20 seconds
Instrument consumption current: 30mA,
Battery operation time: 100 hours
Low operating range: temperature - 10 ℃ ~ + 40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106 kpa
==================================================================
4) Octane number tester
Model : BI-133
Brief introduction:
BI-133 octane number detector is a new generation of octane value measuring instruments, adopt international advanced measuring principle, according to the diversity of domestic oil product design and development, fill the blank of the variety of product testing, with precise and can quickly detect the octane value of the product, both Chinese and English two languages, the large capacity data storage and can print directly measured values, page design humanized operation is simple, LAB133 octane number tester adopts imported case and chips, sensors use alloy metal seal design, super long standby, a charging circuit suitable for on-site, field and laboratory work.
Main features:
1.BI-133 can quickly detect the octane number of gasoline.
2. After long-term data collection, the instrument has a complete database and is integrated with new technology to develop a variety of detection modes, which can detect vehicle gasoline and ethanol gasoline
(zhuanli technology, the only equipment in China that can test the index), high octane oil, low octane oil, methanol gasoline, and other oil products, to fill in the blank of octane number of some oil products.
3. Introduced the international dielectric constant measurement principle, designed and developed according to the Chinese market demand, and included the advantages of the original domestic testing instruments.
4. Quick and accurate detection, simple operation, large screen Chinese display, EL backlight support, easy to use in dim light environment, host panel Chinese menu operation
5. The original imported instrument shell is strong and durable, small and easy to carry. The chip and core components are imported with original packaging, which increases the sensitivity and service life of the instrument.
Sensor alloy metal seal manufacturing, the outer packing box has high strength, high impact resistance, excellent sealing waterproof, moisture-proof, dustproof, enclosed square sponge.
6. The upper and lower limits of the mode can be set in advance, and the exceeded range will be displayed automatically for the convenience of user detection.
7. With automatic shutdown energy saving function, low power consumption design, 4 sections of rechargeable batteries, recyclable charging, battery reliability is stronger.
Principle of measurement:
The principle of octane number tester is to determine the magnetic conductivity of gasoline octane number insulation and electromagnetic induction charge characteristics.
The results are obtained by measuring the dielectric properties of the oil and comparing them with the known in-memory data models.
The sensor is very accurate and can measure tiny dielectric parameter changes, so as to detect octane number and other parameters of petroleum products.
Technical parameters:
Measuring item: automobile gasoline.
Octane number measurement in accordance with: ASTM d2699-86, ASTM d2700-86.
Low operating range: temperature - 10 ℃ ~ + 40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106 kpa
BI-133 octane number detector is a new generation of octane value measuring instruments, adopt international advanced measuring principle, according to the diversity of domestic oil product design and development, fill the blank of the variety of product testing, with precise and can quickly detect the octane value of the product, both Chinese and English two languages, the large capacity data storage and can print directly measured values, page design humanized operation is simple, LAB133 octane number tester adopts imported case and chips, sensors use alloy metal seal design, super long standby, a charging circuit suitable for on-site, field and laboratory work.
Main features:
1.BI-133 can quickly detect the octane number of gasoline.
2. After long-term data collection, the instrument has a complete database and is integrated with new technology to develop a variety of detection modes, which can detect vehicle gasoline and ethanol gasoline
(zhuanli technology, the only equipment in China that can test the index), high octane oil, low octane oil, methanol gasoline, and other oil products, to fill in the blank of octane number of some oil products.
3. Introduced the international dielectric constant measurement principle, designed and developed according to the Chinese market demand, and included the advantages of the original domestic testing instruments.
4. Quick and accurate detection, simple operation, large screen Chinese display, EL backlight support, easy to use in dim light environment, host panel Chinese menu operation
5. The original imported instrument shell is strong and durable, small and easy to carry. The chip and core components are imported with original packaging, which increases the sensitivity and service life of the instrument.
Sensor alloy metal seal manufacturing, the outer packing box has high strength, high impact resistance, excellent sealing waterproof, moisture-proof, dustproof, enclosed square sponge.
6. The upper and lower limits of the mode can be set in advance, and the exceeded range will be displayed automatically for the convenience of user detection.
7. With automatic shutdown energy saving function, low power consumption design, 4 sections of rechargeable batteries, recyclable charging, battery reliability is stronger.
Principle of measurement:
The principle of octane number tester is to determine the magnetic conductivity of gasoline octane number insulation and electromagnetic induction charge characteristics.
The results are obtained by measuring the dielectric properties of the oil and comparing them with the known in-memory data models.
The sensor is very accurate and can measure tiny dielectric parameter changes, so as to detect octane number and other parameters of petroleum products.
Technical parameters:
Measuring item: automobile gasoline.
Octane number measurement in accordance with: ASTM d2699-86, ASTM d2700-86.
Low operating range: temperature - 10 ℃ ~ + 40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106 kpa
===============================================================
5) Diesel cetane number tester
MODEL : QX-D
Summary:
BI-QX-D gasoline octane number diesel hexadecane number tester is used for mechanized troops, petroleum refining enterprises, oil storage and oil regulating units to quickly determine: automotive gasoline, aviation gasoline and ethanol gasoline octane number, diesel hexadecane number handheld special instrument. This instrument adopts miniaturized and humanized design. It is a handheld instrument with simple operation, fast measuring speed, high precision and wide range. The four technological innovations are as follows:
1. The sensor signal adopts digital transmission technology, with strong anti-interference ability, small variation and high precision: reproducibility and repeatability.
2. The calibration program of the instrument is automatic value assignment and calibration, which adopts rigorous mathematical model and can be automatically assigned and calibrated by measuring operation. The program is simple, scientific and accurate.
Users can do their own calibration maintenance, convenient for users.
3. The automatic regression of measurement procedure is based on the rigorous mathematical model, by means of high-precision sensor and electronic measurement technology and ASTM -- CFR testing machine test results as the standard sample, targeted automatic regression is conducted to improve the measurement accuracy and range.
4, the development of the above procedures, do not need to gear a key measurement, the instrument has been through automatic regression, the national standard gasoline, aviation gasoline, diesel oil for a key measurement (referred to as a key), screen display research method, motor method and anti-explosion index three (referred to as a screen three).
Working principle:
The octane number of gasoline and cetane number of diesel oil are derived by measuring the dielectric constant of oil components.
Based on the theory of the rigorous mathematical model, by means of high precision sensors and advanced electronic measurement technology, especially on the basis of CFR tester determination results, targeted to return sample, after the handover procedure is used to test the same sample is consistent with the CFR tester is used to test results, CFR tester is dissemination of BI-QX - C.
Technical performance:
1, the working environment: the environment temperature is 10 ℃ ~ 35 ℃, relative humidity of 85% or less
2. Measuring range:
(1) vehicle steam:
1. National standard: 70.0 ~ 110.0/RON
2. Blending: 75.0 ~ 110.0/RON
Ethanol: e93:92.0 ~ 95.0/RON. 6. Judgment: 60.0 ~ 120.0/RON
4. Manganese base: 85.0 ~ 110.0/RON
5. Methanol :(reserved M5 ~ M25)
6. Judgment: 60.0 ~ 120.0/RON
E97:95.0 ~ 99.0 / RON
(2) raw materials:
Light weight: 50.0 ~ 80.0/MON
Aromatics: 95.0 ~ 120.0/RON
(3) aviation steam: 87.0 ~ 105.0/MON
(4) diesel fuel: 25 ~ 75/CN (cetane number)
20 ~ 80/CI (cetane index)
3. Accuracy:
Aviation steam: 1.5/MON
Automotive: 1.5/RON 1.5/MON
Vehicle fuel: 2.6/CN 2.6/CI
Retest of the regression sample: 0.5/RON 0.5/MON
Field test of regression samples: 1.5/RON 1.5/MON
Calibration accuracy: 0.2/RON
4. Precision (95% confidence level) reproducibility: 0.5/RON repeatability: 0.2/RON
5. Minimum indexing: 0.1/RON 0.1/MON
6. Response time: 1S
7. Measurement results: liquid crystal display, storage and printing
8. Overall size: handheld host: 210 x 100 x 40 mm
9. Power supply: AC220V 10V/ 4.2v host rechargeable battery power supply
10. The instrument is a 16 keyboard (the left number at the bottom of graphic omission is printer, charger and sensor interfaces respectively).
BI-QX-D gasoline octane number diesel hexadecane number tester is used for mechanized troops, petroleum refining enterprises, oil storage and oil regulating units to quickly determine: automotive gasoline, aviation gasoline and ethanol gasoline octane number, diesel hexadecane number handheld special instrument. This instrument adopts miniaturized and humanized design. It is a handheld instrument with simple operation, fast measuring speed, high precision and wide range. The four technological innovations are as follows:
1. The sensor signal adopts digital transmission technology, with strong anti-interference ability, small variation and high precision: reproducibility and repeatability.
2. The calibration program of the instrument is automatic value assignment and calibration, which adopts rigorous mathematical model and can be automatically assigned and calibrated by measuring operation. The program is simple, scientific and accurate.
Users can do their own calibration maintenance, convenient for users.
3. The automatic regression of measurement procedure is based on the rigorous mathematical model, by means of high-precision sensor and electronic measurement technology and ASTM -- CFR testing machine test results as the standard sample, targeted automatic regression is conducted to improve the measurement accuracy and range.
4, the development of the above procedures, do not need to gear a key measurement, the instrument has been through automatic regression, the national standard gasoline, aviation gasoline, diesel oil for a key measurement (referred to as a key), screen display research method, motor method and anti-explosion index three (referred to as a screen three).
Working principle:
The octane number of gasoline and cetane number of diesel oil are derived by measuring the dielectric constant of oil components.
Based on the theory of the rigorous mathematical model, by means of high precision sensors and advanced electronic measurement technology, especially on the basis of CFR tester determination results, targeted to return sample, after the handover procedure is used to test the same sample is consistent with the CFR tester is used to test results, CFR tester is dissemination of BI-QX - C.
Technical performance:
1, the working environment: the environment temperature is 10 ℃ ~ 35 ℃, relative humidity of 85% or less
2. Measuring range:
(1) vehicle steam:
1. National standard: 70.0 ~ 110.0/RON
2. Blending: 75.0 ~ 110.0/RON
Ethanol: e93:92.0 ~ 95.0/RON. 6. Judgment: 60.0 ~ 120.0/RON
4. Manganese base: 85.0 ~ 110.0/RON
5. Methanol :(reserved M5 ~ M25)
6. Judgment: 60.0 ~ 120.0/RON
E97:95.0 ~ 99.0 / RON
(2) raw materials:
Light weight: 50.0 ~ 80.0/MON
Aromatics: 95.0 ~ 120.0/RON
(3) aviation steam: 87.0 ~ 105.0/MON
(4) diesel fuel: 25 ~ 75/CN (cetane number)
20 ~ 80/CI (cetane index)
3. Accuracy:
Aviation steam: 1.5/MON
Automotive: 1.5/RON 1.5/MON
Vehicle fuel: 2.6/CN 2.6/CI
Retest of the regression sample: 0.5/RON 0.5/MON
Field test of regression samples: 1.5/RON 1.5/MON
Calibration accuracy: 0.2/RON
4. Precision (95% confidence level) reproducibility: 0.5/RON repeatability: 0.2/RON
5. Minimum indexing: 0.1/RON 0.1/MON
6. Response time: 1S
7. Measurement results: liquid crystal display, storage and printing
8. Overall size: handheld host: 210 x 100 x 40 mm
9. Power supply: AC220V 10V/ 4.2v host rechargeable battery power supply
10. The instrument is a 16 keyboard (the left number at the bottom of graphic omission is printer, charger and sensor interfaces respectively).
=================================================================
6) Gasoline octane number tester
Model : BI-130
Introduction:
BI130 is a portable, all-digital gasoline octane number tester that can be quickly and easily, accurately, without damaging the octane number of the gasoline sample and the cetane number of the diesel, both for the laboratory , Can also be used for field testing. It is the first domestic can detect gasoline octane number, also applies to diesel cetane instrument. It uses the dielectric constant method to detect octane number and cetane number detection technology, in full compliance with international standards (ASTM D2699-86, ASTM D2700-86), commonly used in the analysis of power gasoline and diesel quality, with the research method RON, motor The method MON corresponds to the cetane number CN.
Features:
1 Measure gasoline octane number and diesel cetane number
2 with the most authoritative domestic gasoline octane number and diesel cetane number database
3 repeatable error range is 0.2 octane units
4 A variety of additives containing gasoline can be measured
5 also shows RON, MON and anti-blast index (AKI).
6 measurement of diesel cetane number CN, diesel type
7 powerful processing chip can be fast and accurate data processing
8 The instrument is equipped with six oil test data models to suit the various conditions of the oil measurement
9 easy to operate, small size, easy to carry, box anti-vibration, anti-solvent, sealed, the use of low cost
10 through the RS232 data transmission line can be connected to the computer, the computer can be directly operated and printed
11 Traditional octane number test machine and cetane number testing machine need professional and technical personnel operation, the process is cumbersome, and need to consume a large number of reference fuel, equipment maintenance costs are expensive, so that ordinary users to determine the octane number of cetane There is a lot of difficulty. The rapid measurement of fuel for Lab130 is more efficient than traditional methods.
Technical Parameters:
Measurement items: all kinds of gasoline, diesel
Octane measurements are met: ASTM D2699-86, ASTM D2700-86.
Diesel cetane measurements are met: ASTM D4737-03, ASTM D613, EN ISO 5165.
Measuring range: octane number: 40-120 (accuracy ± 0.5), cetane number: 20-100 (accuracy ± 1)
Measurement time for each sample: <8 seconds
Instrument consumption current: 30mA,
Battery standby time: 100 hours
Operating range: temperature -10 ℃ ~ +40 ℃, relative humidity 30% ~ 81% R.H., atmospheric pressure 64 ~ 106kPa
Dimensions
Sensor: 60mm × 100mm,
Host: 236mmx130mmx43mm
=================================================================
7) Gasoline and diesel dual - use analyzer
Model : BI-GT
Introduction:Portable gasoline octane diesel cetane number (referred to as gasoline and diesel dual-use) detector, is used for mechanized forces, oil refining enterprises, oil storage and oil unit rapid determination: aviation gasoline, gasoline, gasoline , Ethanol gasoline and methanol gasoline octane number, diesel cetane number and cetane index (calculation method) hand-held special pocket instrument. The instrument uses a small, user-friendly design, with a simple operation, easy to carry, the determination of fast, high precision, wide range, full-featured features.
Features:
1 • Sensor signal using digital transmission technology, anti-interference ability, small variation, high precision: reproducibility, repeatability is very good.
2 • The calibration procedure of the instrument is automatic assignment calibration, the rigorous mathematical model, the determination of the operation can be automatically assigned calibration, the program is simple, scientific method, accurate and reliable. Customers can do their own maintenance calibration, to facilitate customers.
3 • Automatic return of the measurement program is based on the rigorous mathematical model, with advanced electronic measurement technology as a means (high-precision sensor), ASTM-CFR test machine as a standard, targeted regression, targeted , And the measurement accuracy and the measurement range were improved.
4) The development of the above procedures can be done by a key test, the instrument has passed the pre-return, the national standard gasoline, aviation gasoline, vehicle diesel to achieve a key determination (referred to as a push), screen display research, motor and anti- Burst index (referred to as a screen three).
.
.
.
.
.
.
Langganan: