Rabu, 26 Januari 2022

081362449440 Jual Macherey Nagel Infonesia , Jual Photo Meter PF12 , Jual Visocolor Nanocolor PF3 Jual QUANTOFIX RELAX , Jual Visocolor Reagent School , Jual MULTIPARAMETER PHOTOMETER PLUMBTESMO 906 02 INDONESIA DISTRIBUTOR

BINTANG INSTRUMENT
HP. 081362449440 , 081310157965 
Email : b081362449440@yahoo.com
Up : Mr Jonathan
=====================================
MACHEREY NAGEL INDONESIA





































VISOCOLOR ALPHA
-     Visual evaluation
-     Environment-friendly, without hazardous goods
-     Low-priced

-     Convenient handling, as easy as dip sticks
-     Accurate results
-     Handy packages
-     Reagent bottles with clear dosing instructions
-     With pictographic instructions
-   Colorimetry with colour comparison card
- Titration with drop counting

Ammonium

-
935 012 range : 0-0.2-0.5-1-2-3 mg/l  NH4 50




Carbonate hardness
935 016 range : 1 drop = 1 0d 100




Chlorine
935 019 range : 0.25-0.5-1.0-1.5-2.0 mg/I Cl2 150




Total Hardness
935 042 range: 1 drop = 1 0d 100




Residual Hardness
935 080 range: 0.00-0.04-0.08-0.15-0.30 0d 200




Nitrate

-
935 065 range : 2-8-15-30-50 mg/I NO3 •• 100




Nitrite

-
935 066 range : 0.05-0.10-0.25-0.5.1.0 mg/I NO2 200




pH 5 – 9
935 075 range : pH 5.0-5.5-6.0-6.5-7.0-7.5-8.0-8.5-9.0 200




Phosphate

3-
935 079 range : 2-5-10-15-20 mg/I PO4 70



VISOCOLOR ECO
-     Environment-friendly, without toxic reagent
-     Economically priced
-     Convenient handling
-     Higher accuracy and sensitivity
-     Reagent bottles with clear dosing instructions
Colorimetry with colour comparison card
-     Visual and photometric evaluation (with PF 11/ photino)
-     With pictographic instructions
-     Compensation of turbidities and colours
-     Refill pack available
Filtration with drop counting
-     Sha,er colour change due to separated dropping reagents

Aluminium
931 006 range : 0-0.10-0.15-0.20-0.25-0.30-0.40-0.50 mg/l Al 50
931 206 Refill pack 50




Ammonium 3
931 008 range : 0-0.2-0.3-0.5-0.7-1-2-3 mg/I NH + 50

4
931 208 Refill pack 50




Ammonium 15
931 010 range : 0-0.5-1-2-3-5-7-10-15 mg/I NH + 50

4
931 210 Refill pack 50




Calcium
931 012 range : 1 drop = 5 mg/I Ca 100




Carbonate hardness
931 014 range : 1-10 1 0d  and higher 100




Chlorine 2
931 015 range : <0.1-0.1-0.2-0.3-0.4-0.6-0.9-1.2-2.0 mg/I Cl2 150
931 215 Refill pack 150




free Chlorine 2
931 016 range : 0.1-0.1-0.2-0.3-0.4-0.6-0.9-1.2-2.0 mg/l  Cl2 150
931 216 Refill pack 150













Chloride
931 018 range : 0-1-2-4-7-12-20-40-60 mg/I Cl-• 90
931 218 Refill pack 90




Chromium (VI)
931 020 range :0.00-0.02-0.05-0.10-0.15-0.20-030-0.40 140

0.50mg/lCr (IV)
931 220 Refill pack 140




Chlorine Dioxide
931 021 range : 0.2-0.4-0.6-0.8-1.1-1.7-2.3-3.8 mg/L ClO2 150
931 221 Refill pack 140




Cyanide
931 022 range : 0-0.01-0.02-0.03-0.05-0.07-0.10-0.15-0.20 mg/l CN- 100
931 222 Refill pack 100




Cyanuric acid
931 023 range : 10-15-20-30-40-60-80-100 mg/I Cya 100
931 223 Refill pack 100




DEHA (diethylhydroxylamine)
931 024 range : 0-0.01-0.03-0.05-0.10-0.15-0.20-0.25-0.30mg/I DEHA 125
931 224 Refill pack 125




Iron 1
931 025 range : 0-0.04-0.07-0.10-0.15-0.20-0.30-0.50- 200

1.0 mg/I Fe
931 225 Refill pack 200




Iron
931 026 range : 0-0.04-0.07-0.10-0.15-0.20-0.30-0.50- 100

1.0 mg/I Fe
931 226 Refill pack 100




Total Hardness
931 029 range : 1 – 10 0d and higher 110




Hydrazine
931 030 range : 0-0.05-0.10-0.15-0.20-0.25-0.30- 130

0.40 mg/l N2H4
931 230 Refill pack 130




Potassium
931 032 range : 2-3-4-6-8-10-15 mg/l K 60
931 232 Refill pack 60

Silica
931 033 range : 0-0.2-0.4-0.6-1.0-1.5-2.0-2.5-3.0 mg/l SiO2 100
931 233 Refill pack 100




Copper
931 037 range : 0-0.1-0.2-0.3-0.5-0.7-1.0-1.5 mg/I Cu 100
931 237 Refill pack 100




Manganese
931 038 range : 0-0.1-0.2-0.3-0.5-0.7-0.9-1.2-1.5 mg/l Mn 70
931 238 Refill pack 70




Nickel
931 040 range : 0-0.1-0.2-0.3-0.5-0.7-0.9-1.2-1.5 mg/I Ni2+ 150
931 240 Refill pack 150




Nitrate
931 041 range : 0-1-3-5-10-20-30-50-70-90-120 mg/INO3- 110
931 241 Refill pack 110




Nitrite
931 044 range : 0-0.02-0.03-0.05-0.07-0.1-0.2-0.3-0.5 mg/I NO•2- 120
931 244 Refill pack 120




pH 4.0 - 9.0
931 066 range : 4.0-5.0-6.0-6.5-7.0-7.5-8.0-8.5-9.0 pH 450
931 266 Refill pack 450




Phosphate
931 084 range : 0-0.2-0.3-0.5-0.7-1-2-3-5  mg/l  PO4-P 80
931 284 Refill pack 80




Oxygen
931 088 range : 0-1-2-4-8-8-10 mg/I 50
931 288 Refill pack 50




Swimming Pool (chlorine + ph)
931 090 range : 0.1 – 2.0 mg/l Cl2 range : 6.9 – 8.2 pH 150


150
931 290 Refill pack 150




Sulphate
931 092 range : 25-30-35-40-50-60-70-80-100-120-150-200 mg/L SO42- 150
931 292 Refill pack 150




Sulphide
931 094 range : 0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8 mg/l S2- 90
931 294 Refill pack 90




Sulphite
931 095 range : 1 drop = 1 mg/I SO32- 60




Zinc
931 098 Range : 0-0.5-1-2-3 mg/l Zn 120
931 298 Refill pack 120



VISOCOLOR HE
Highly sensitive colorimetric test kit. In comparison with conventional VISOCOLOR kits.
Their sensitivity in enchanced by increasing the length of the test tube and the use of highly sensitive reagents.
This technique allows a 10-fold to 100- fold increase of sensitivity.
-     Visual evaluation
-     Economy priced
-     Convenient handling
-     Reagent bottles with clear dosing instructions
-     Refill pack available
COLOMETRIC TEST KIT
High sensitivity colorimetry with comparator block and colour comparison table.
-     Environment-friendly, without toxic reagents
-     Highest accuracy due to extremely narrow gradation
-     Compensation of turbidities and colours
TITRATION TEST KIT
High sensitive volumetric analysis with gradated syringe

Ammonium
920 006 range : 0.02 – 0.50 mg/l NH+ 110
920 106 Refill pack 110




Chlorine
920 015 range : 0.02 – 0.60 mg/l Cl2 2x160
920 115 Refill pack 2x160







Copper
920 050 range : 0.04 – 0.50 mg/l Cu2+ 150
920 150 Refill pack 150




Cyanide
920 028 range : 0.002 – 0.04 mg/l CN- 55
920 128 Refill pack 55




Iron
920 040 range : 0.01 – 0.20 mg/l Fe 300
920 140 Refill pack 300




Manganese
920 055 range : 0.03 – 0.50 mg/l Mn 100



920 155 Refill pack 100




Nitrite
920 063 range : 0.005 – 0.10 mg/l NO - 150

2
920 163 Refill pack 150




PH
920 074 range : 4.0 – 10.0 pH 500
920 174 Refill pack 500




Phosphate
920 082 Range : 0.05 – 1.0 mg/l P 300
920 182 Refill pack 300




Phosphate DEV
920 080 Range : 0.01 – 0.25 mg/l P 100
920 180 Refill pack 100




Silica / Silicon
920 087 Range : 0.01 – 0.30 mg/l SiO2 120
920 187 Refill pack 120



VISOCOLOR COMPARATOR






Packed in a sturdy plastic box, which contains a comparator for colour comparison and all required reagents.
Colorimetry with comparator cell
-     Visual and photometric evaluation (with PF-11)
-     Convenient handling
-     Reagent bottles with clear dosing instructions
-     Comparison of turbidities and colours
-     Refill pack available

Acidity AC7 (base capacity)
915 006 range : 0,2 – 7 mmol/l 200
915 206 Refill pack 200




Alkalinity AL7 (total)
915 007 range : 0,2 – 7 mmol/l 200
915 207 Refill pack 200




Calcium CA 20
915 010 range : 0.5 – 20 0d / 0.1 – 3.6 mmol/l 200
915 210 Refill pack 200




Carbonate hardness C20
915 003 range : 0.5 – 20 0d / 0.2 – 7 mmol/l 200
915 203 Refill pack 200




Chloride CL 500
915 004 range : 5 – 500 mg/l Cl-1 300




Hardness H 20 F (total)
915 005 range : 0.5 – 20 0d / 0.1 – 3.6 mmol/l 200
915 205 Refill pack 200




Hardness H2 (residual)
915 002 range : 0.05 – 2 0d / 0.01 – 0.36 mmol/l 200
915 202 Refill pack 200




Oxygen SA 10
915 009 Range : 0.2 – 10 mg/l O2 100
915 209 Refill pack 100




Sulphite SU 100
915 008 range : 2 – 100 mg/l SO 2- 100

3
915 208 Refill pack 100



QUANTOFIX test sticks for semi-quantitative determinations
QUANTOFIX test sticks meet the most important requirements for a modern quick-test
- rapid            : dip and read
- convenient   : the analysis can be carried out without any further equipment , only a single test stick of  QUANTOFIX is needed
- specific         : QUANTOFIX test sticks are highly specific
possible interferences are eliminated by precipitation of masking



- stable           : shelf life 2½ years after production
(below +30 oC)


Active Oxygen
913 49 Range : 0-4-8-15-25 mg/l KMPS 100




Aluminium
913 07 Range : 0-5-20-50-200-500 mg/l Al 100




Ammonium
913 15 Range : 0-10-25-50-100-200-400 mg/l NH4+ 100




Arsenic 10
913 34 range : 0-0.01-0.025-0.05-0.1-0.5 mg/l As3+/5+ 100




Arsenic 50
913 32 range : 0-0.05-0.1-0.5-1.0-1.7-3.0 mg/l As3+/5+ 100




Arsenic Sensitive
913 45 range : 0-0.005-0.01-0.025-0,05-0,1-0,25-0,5 mg/l As3+/5+ 100




Ascorbic Acid
913 14 range : 0-50-100-200-300-500-700-1000-2000 mg/l Vit.C 100




Calcium
913 24 range : 0-10-25-50-100 mg/l Ca2+ 60




Carbonate Harness
913 23 range : 0-3-6-10-15-20 0d 100




Chloride
913 21 range : 0-500-1000-1500-2000-³3000 mg/l Cl- 100




Chlorine
913 17 range : 0-1-3-10-30-100 mg/l Cl2 100




Chlorine Sensitive
913 39 Range :  0-0,1-0,5-1-3-10 mg/l Cl2 100




Chromate
913 01 Range : 0-3-10-30-100 mg/l CrO 2- 100

4




Cobalt
913 03 range : 0-10-25-50-100-250-500-1000 mg/l Co2+ 100






913 04 range : 0-10-30-100-300 mg/l Cu+/2+ 100




Cyanide
913 18 range : 0-1-3-10-30 mg/l CN- 100




EDTA
913 35 range : 0-100-200-300-400 mg/l EDTA 100




Formaldehyde
913 28 range : 0-10-20-40-60-100-200 mg/l HCHO 100




Glucosa
913 48 range : 0-50-100-250-500-1000-2000 mg/l glucose 100




Glutaraldehyde
913 43 range : 0-0,5-1-1,5-2-2,5% glutaradehyde 100




Total Iron 100
913 44 range : 0-2-5-10-25-50-100 mg/l Fe 100




Total Iron 1000
913 30 range : 0-5-20-50-100-250-500-1000 mg/l Fe 100




LubriCheck
913 36 range : 0-15-50-75-130-200 mg/l KOH 100




Molybdenum
913 25 range : 0-5-20-50-100-250 mg/l Mo6+ 100




Nickel
913 05 range : 0-10-25-50-100-250-500-1000 mg/l Ni2+ 100







Nitrate / Nitrite

-
913 13 range : 0-10-25-50-100-250-500 mg/l NO3 100

range : 0-1-5-10-20-40-80 mg/l NO -

2




Nitrite
913 11 range : 0-1-5-10-20-40-80 mg/l NO - 100

2




Nitrite 3000
913 22 range : 0-0.1-0.3-0.6-1-2-3 g/l NO - 100

2




Nitrite / pH
913 38 range : 0-1-5-10-20-40-80 mg/l NO - 100

2

range : 6,0-6,4-6,7-7,0-7,3-7,6-7,9-8,2-8,4-8,6-8,8-

9,0-9,3-9,6




Paracetic Acid 50
913 40 range : 0-5-10-20-30-50 mg/l peracetic acid 100




Paracetic Acid 500
913 41 range : 0-50-100-200-300-400-500 mg/l peracetic acid 100




Paracetic Acid 200
913 42 range : 0-500-1000-1500-2000 mg/l perecetic 100




Nitrite 3000
913 19 range : 0-0.1-0.3-0.6-1-2-3 g/l NO - 100

2




Peroxide 1000
913 33 range : 0-50-150-300-500-800-1000 mg/l H•2O2 100




Peroxide 100
913 12 range : 0-1-3-10-30-100 mg/l H•2O2 100




Peroxide 25
913 19 range : 0-0.5-2-5-10-25 mg/l H•2O2 100




Phospate
913 20 range : 0-3-10-25-50-100 mg/l PO4 100




Potassium
913 16 range : 0-200-400-700-1000-1500 mg/l K 100




QUAT
913 37 range : 0-10-25-50-100-250-500-1000 mg/l 100




SILVER
913 50 range : 0-1-2-3-5-7-10 g/l Ag 100







Sulfate
913 29 range : <200->400->800->1200->1600 mg/l SO4 100




Sulfite
913 06 range : 0-10-25-50-100-250-500-1000 mg/l SO3 100




Tin
913 09 range : 0-10-25-50100-250-500 mg/l Sn2+ 100




Zinc
913 10 range : 0-2-5-10-25-50-100 mg/l Zn 100




Aquarium Owners

range : 0-5-10-15-20-25 0d total hardness range : 0-3-6-10-15-20 0d carbonate hardness range : 6.4-6.8-4.2-7.6-8.0-8.4 pH
913 26
100



TEST PAPERS for qualitative determinations






Test papers allow the qualitative detection of ions and
chemical substances.






They provide the information, whether a given component is present above the defined limit of detection



Some test papers can also be used for the non-destructive
testing of materials






906 12 Phosphatesmo MI

Determination of : Alkaline phosphatase in milk 50 sticks



907 21 Aluminium test paper

Determination of : Aluminium ions (Al3+) 100 strips



907 22 Ammonium test paper

+ 200 strips

Determination of : Ammonia, ammonium ions (NH3, NH4  )



907 23 Antimony test paper

Determination of : Antimony ions(Sb3+) 200 strips



907 62 Arsenic test paper = mercury bromide paper

Determination of : Arsenic, arsine (As, AsH3) 200 strips






907 33 Bismuth test paper

Determination of : Bismuth ions (Bi3+) 200 strips



906 05 Peroxtesmo KM

Determination of : Blood traces (peroxidase) 25 sheets



907 47 Tumeric paper

3- 200 strips

Determination of : Boric Acid , borates ( H3 BO3, BO3   )



906 03 Chlortesmo

Determination of : Chlorine, free halogen 200strips



907 24 Chromium test paper

+2- 200 strips

Determination of : Chromium, chromate (Cr(VI), CrO4     )









907 28 Cobalt test paper

Determination of : Cobalt ions (Co2+) 100 strips



906 01 Cuprotesmo

Determination of : Copper, copper ions (Cu, Cu+, Cu2+) 40 sheets



907 29 Copper test paper

Determination of : Copper (II) ions (Cu2+) 200 strips



906 04 Cyantesmo Reel 5 m

Determination of : Cyanides, hydrocyanic acid (CN-, HCN) Length



907 50 Fluoride test paper

Determination of : Fluorides, hydrogen fluoride (F-, H F ) 200 strips

2  2



906 03 Chlortesmo

Determination of : Halogens, especially free chlorine 200 strips



906 04 Cyantesmo Reel 5 m

Determination of : Hydrocyanic acid, cyanides (HCN, CN-) Length



907 44 Lead Acetate paper Reel 5 m

Determination of : Hydrogen sulphide (H2S), sulphide ions Length

(S2)



907 45 Lead acetate paper Refill pack (3 reels) Pack



907 46 Lead acetate paper  booklet with 100 strips 10x75 mm Pack






907 25 Dipyridyl paper

Determination of : Iron (II) ions (Fe2) 200 strips



907 26 Iron test paper

Determination of : Iron ions (Fe2+, Fe3+) 100 strips



906 27 Peroxtesmo MI

Determination of : Lactoperoxidase in milk 100 sheets



906 02 Plumbtesmo

Determination of : Lead, lead ions (Pb, Pb2+) 40 sheets



907 48 Udder test paper

Determination of : Mastitis 20 sheet



907 30 Nickel test paper

Determination of : Nickel (II) ions (Ni2+) 200 strips



906 11 Nitratesmo Reel 5 m

-           - length

Determination of : Nitrate and nitrite (NO3 , NO2 )



907 54 Potassium Iodide starch paper Reel 5 m

- Length

Determination of : Nitrite ions (NO2 )



907 55 Potassium iodide starch paper  refill pack with 3 reels Pack



907 60 Oil test paper

Determination of : Oil in water and soil 100 strips



907 42 AUATEC test sticks

Determination of : oil, thickness of layer in oil separators 100 sticks



906 06 Peroxtesmo KQ

Determination of : Peroxidase in foodstuffs 100 strips



906 27 Peroxtesmo MI

Determination of : Peroxidase in milk 100 sheets



907 27 Potassium test paper

Determination of : Potassium ions (K+) 200 strips



907 65 INDIPRO

Determination of : Protein residues 60 sticks



907 53 Potassium Ioadate starch paper Reel 5 m

Determination of : Reducing agents, SO2, sulphite ions Length






907 63 Sulphite test paper

Determination of : Sulphur dioxide (SO2), sulphite ions 100 strips



907 32 Silver test paper

Determination of : Silver ions(Ag+) 200 strips



906 07 Phosphatesmo KM

Determination of : Sperm, acid phosphatase 25 sheets



907 51 Indanthrene yellow paper

Determination of : Vat dyes, and-point of conversion 200 strips



907 42 AQUATEC test sticks

Determination of : Water on the bottom of fuel thank 100 stick



906 09 Watesmo Reel 5 m

Determination of : Water in org. solvents Length



906 10 Wator

Determination of : Water distribution in buffer 50 sheets



907 21 Zirconium test paper

Determination of : Zirconium ions (Zn4+) 100 strips



TEST PAPER for semi-quantitative determinations




Ag-Fix (test stick) Determination of  :silver and pH Range : 0-0.5-1-2-3-5-7-10 g/l Ag+ Range : 4-5-6-7-8 pH



907 41
100




AQUADUR
912 01 Determination of : water hardness

Range : <3, >5, >10, > 15, >20, >25, 0d


100




AQUADUR
912 20 Determination of : water hardness

Range : <3, >4, >7, >14, >21  0d


100




Chlorine Test
907 09 Determination of : chlorine Reel 5 m length

Range : 10 – 50 – 100 – 200 mg/l Cl2




Fluoride test 30 test disks + reagent
907 34 Determination of : fluoride ions

Range : 0-2-5-10-20-50-100 mg/l F-







Ozone test sticks
907 36 Determination of : Ozone content in water 12

Range : <90, 90-150, 150-210, >210 mg/m3 O

3




Saltesmo
906 08 Determination of : Halide ions 30

Range : 0-0.25-0.5-1-2-3-4-5 g/l NaCl




Swimming pool

Determination of : free chlorine, alkalinty and pH Range :  0-05-1-3-5-10 mg/l (ppm) Cl2

0-80-120-180-240 mg/l (ppm) Ca Co3
907 52 6.4-6.8-7.2-7.6-8.4 pH 50



UNIVERSAL and SPECIAL INDICATOR PAPERS






These products are produced by total impregnation of the paper with a pH indicator or a mixture of several indicator dyes.



This indicator paper is left in the test tube and its colour,
viewed through the glass, is compared with the colour scale after about 1 minute.
902 01 pH 1 – 11 Reel

range  : 1-2-3-4-5-6-7-8-9-10-11
902 02 Refill pack  (pack of 3 reel) Reel



902 03 pH 1 – 11 Booklet

range  : 1-2-3-4-5-6-7-8-9-10-11



902 04 pH 1 – 14 Reel

range  : 1-2-3-5-6-7-8-9-10-12-14
902 24 Refill pack  (pack of 3 reel) Reel



902 05 pH 0.5 – 5.5 Reel

range  : 0.5-1.0-1.5-2.0-2.5-3.0-3.5-4.0-4.5-5.0-5.5
902 25 Refill pack  (pack of 3 reel) Reel



902 06 pH 3.8 – 5.8 Reel

range  : <3.8-3.8-4.1-4.3-4.5-4.7-4.9-5.2-5.5-5.8->5.8
902 26 Refill pack  (pack of 3 reel) Reel






902 07 pH 4.0 – 7.0 Reel

range : 4.0-4.3-4.6-4.9-5.2-5.5-5.8-6.1-6.4-6.7-7.0
902 27 Refill pack  (pack of 3 reel) Reel



902 08 pH 5.4 – 7.0 Reel

range : <5.4-5.4-5.7-6.0-5.2-6.4-6.7-7.0-.7.0
902 28 Refill pack  (pack of 3 reel) Reel



902 08 pH 5.4 – 7.0 Reel

range : <5.4-5.4-5.7-6.0-5.2-6.4-6.7-7.0-.7.0
902 28 Refill pack  (pack of 3 reel) Reel



902 09 pH 5.5 – 9.0 Reel

Range : 5.5-6.0-6.5-7.0-7.5-8.0-8.5-9.0
902 29 Refill pack  (pack of 3 reel) Reel



902 10 pH 6.4 – 8.0 Reel

Range : <6.4-6.4-6.6-6.8-7.0-7.2-7.4-7.6-7.8-8.0->8.0
902 30 Refill pack  (pack of 3 reel) Reel



902 11 pH 7.2 – 9.7 Reel

range : <7.2-7.2-7.5-7.8-8.1-8.4-8.7-9.0-9.3-9.7->9.7
902 31 Refill pack  (pack of 3 reel) Reel



902 12 pH 8.0 – 10.0 Reel

Range : 8.0-8.2-8.4-8.7-9.0-9.2-9.6-10.0
902 32 Refill pack  (pack of 3 reel) Reel



902 13 pH 9.0 – 13.0 Reel

Range : 9.0-9.5-10.0-10.5-11.0-11.5-12.0-12.5-13.0
902 33 Refill pack  (pack of 3 reel) Reel



902 14 pH 12.0 – 14.0 Reel

Range : 12.0-12.5-13.0-13.5-14.0
902 34 Refill pack  (pack of 3 reel) Reel



902 19 PH-Set U – 10

10 differenent reel of pH indicator paper, consist of : Pack

-      2 reels of universal indicator paper

-      8 reels of different special indicator papers






902 18 TRI – BOX

Plastic dispenser with 3 reels of special indicator paper each Pack

5 m long and 7 mm wide, consist of :

-      1 reel pH 0.5 – 5.5

-      1 reel pH 5.5 - 9.0

-      1 reel pH 9.0 - 13.0

-      3 colour scales



Reel : plastic dispenser with colour scale and 1 reel 5 m long and 7 mm wide, packed in individual cardboard box
Refill pack   : box with 3 reels 5 m long 7 mm wide, each reel separately sealed in polyethylene
Booklet : 100 strips 10 x 70 mm with colour scale
DUOTEST double-zone indicator paper






- Duotest papers are indicator papers with greater accuracy and increased ease of reading. Two complementary indicator zones on one strip
- separated by a white center band- guarantee clear colour differentiation and a more accurate estimate of intermediate values.
- The white center band is hydrophobic and prevents that colours
of the two indicator zones run into one other , thus increasing accuracy.
- In addition the white band forms a good contrast to coloured test zones and furthermore adds mechanical strength to the wet strip, because
it repels water

903 01 pH 1 - 12 Reel

range  : 1-2-3-4-5-6-7-8-9-10-11-12
903 11 Refill pack  (pack of 3 reel) Reel



903 02 pH 1.0 – 4.3 Reel

range  : 1.0-1.3-1.6-1.9-2.2-2.5-2.8-3.1-3.4-3.7-4.0-4.3
903 12 Refill pack  (pack of 3 reel) Reel



902 03 pH 3.5 – 6.8 Reel

range : 3.5-3.8-4.1-4.4-4.7-5.0-5.3-5.6-5.9-6.2-6.5-6.8
903 13 Refill pack  (pack of 3 reel) Reel



902 04 pH 5.0 – 8.0 Reel

range : 5.0-5.3-5.6-5.9-6.2-6.5-6.8-7.1-7.4-7.7-8.0
903 14 Refill pack  (pack of 3 reel) Reel



902 05 pH 7.0 –10.0 Reel

range : 7.0-7.3-7.6-7.9-8.2-7.5-8.85-9.1-9.4-9.7-10.0
903 15 Refill pack  (pack of 3 reel) Reel
902 06 pH 9.5 – 14.0 Reel

range : 9.5-10.0-10.5-11.0-11.5-12.0-12.5-13.0-13.5-14
903 16 Refill pack  (pack of 3 reel) Reel



Collection of DUOTEST Indicator paper
PH-Set D10

903 19       10 reel of DUOTEST, consist of :                                                                  2.162.000
-      2 reel PH 1 - 12
-      2 reel pH 3.5 – 6.8
-      2 reel pH 5.0 – 8.0
-      2 reel pH 7.0 – 10.0
-      1 reel pH 1.0 – 4.3
-      1 reel pH 9.5 – 14.0
TRITEST Triple-zone indicator paper
TRITEST paper is an indicator combining highes accuracy with greatest ease of reading. Three complementary indicator zones on a single strip guarantee clear colour differentiation and the possibility to estimate
in between values. The gradation is 1.0 pH unit. TRITEST is available
for the range pH 1-11










TRITEST in reel form (without hydrophobic zone)

Paper strip of 10 mm width to which three adjoining indicator zones (1 main indicator and 2 auxiliary indicators) have been applied




TRITEST pH 1 –11

Range : 1-2-3-4-5-6-7-8-9-10-11






905 01
Reel



905 02 Refill pack  (pack of 3 reel) Reel




TRITEST L in reel form (with 2 hydrophobic zone)

Paper strip of 6 m length and 14 mm width to which three indicator zones (1 main indicator and 2 auxiliary indicators) have been applied. The indicator zones are separated by hydrophobic barriers. This guarantees a sha, separation of the indicator zones which is of particular advantage in pH determinations in highly alkaline range

TRITEST L  pH 1 –11

Range : 1-2-3-4-5-6-7-8-9-10-11
905 10
Reel



905 11 Refill pack  (pack of 3 reel) Reel



Reel : plastic dispenser with colour scale and 1 reel, packed in individual cardboard box
Reel size  : DUOTEST and TRITEST: 5 m long and 10 mm wide. TRITEST L : 6 m long and 14 mm wide
Refill pack   : box with 3 reels, each reel separately sealed in polyethylene






PEHANON indicator papers
For pH measurement in coloured solutions
PEHANON is a series of ph indicator papers where the indicator and colour scale are combined on a single strip. They permit a fast ,convenient and and accurate determination of the pH value since they eliminate
the necessity to compare the colour field against a separate scale. PH values are imprinted on the strips. This presentation also permits the pH measurement of coloured solutions and suspensions
since the colour of the test solution acts on the colour scale
in the same manner as on the indicator field, resulting in a comparison of mixed colours. The individual colour zones are separated by hydrophobic barrier.






PEHANON papers guarantee highest accuracy even when testing coloured solution! Again-as with universal and special indicator papers-best results are obtained for
buffered solutions and suspensions

pH 1-12
904 01 range : 1-2-3-4-5-6-7-8-9-10-11-12 200




pH 0 – 1.8
904 11 range : 0-0.3-0.6-0.8-1.0-1.2-1.5-1.8 200




pH 1.0 – 2.8
904 12 range : 1.0-1.3-1.6-1.8-2.0-2.2-2.5-2.8 200




pH 1.8 – 3.8
904 13 range : 1.8-2.1-2.4-2.7-3.0-3.2-3.5-3.8 200




pH 2.8 – 4.6
904 14 range : 2.8-3.1-3.4-3.6-3.8-4.0-4.3-4.6 200




pH 3.8 – 5.5
904 15 range : 3.8-4.0-4.2-4.4-4.6-4.9-5.2-5.5 200




pH 4.0 – 9.0
904 24 range : 4.0-4.5-5.0-5.5-6.0-6.5-7.0-7.5-8.0-8.5-9.0 200




pH 5.2 – 6.8
904 16 range : 5.2-5.5-5.7-5.9-6.1-6.3-6.5-6.8 200




pH 6.0 – 8.1
904 17 range : 6.0-6.3-6.6-6.9-7.2-7.5-7.8-8.1 200

pH 7.2 – 8.8
904 19 range : 7.2-7.4-7.6-7.8-8.0-8.2-8.5-8.8 200




pH 8.0 – 9.7
904 20 range : 8.0-8.2-8.4-8.6-8.8-9.1-9.4-9.7 200




pH 9.5 - 12.0
904 21 range : 9.5-10.0-10.5-11.0-11.5-12.0 200




pH 10.5 – 13.0
904 22 range : 10.5-11.0-11.5-12.0-12.5-13.0 200




pH 12.0 – 14.0
904 23 range : 12.0-12.5-13.0-13.5-14.0 200



Plastic box containing 200 strips 11x100 mm









PH-Fix indicator sticks – non bleeding
Recommended for pH measurement in weakly buffered or strongly alkaline solutions






PH-Fix indicator sticks are for the rapid measurement of of the pH of a water sample



In contrast to standard test papers, the pH-Fix indicator is chemically bound to the cellulose fibres, avoiding bleeding even in strongly alkaline samples.
Furthermore there are the following advantages :
- Measurement of pH values is possible even in unbuffered solution, since the sticks can be left in the solution until until the final reaction   colour is obtained
-     Test samples are not contaminated by the indicator dyes.
Thus solution can be used for further investigations.
-     Colour of individual colour fields cannot run into each other.
This allows a more precise comparison the colour scale.
- Specially developed indicator dyes guarantee a sha, differentiation between the individual pH values and a clear and easy comparison with the colour scale
-    Length and stability of plastic strips protect finger from
contact with the test solution

pH 0 – 14
921 10 range : 0-1-2-3-4-5-6-7-8-9-10-11-12-13-14 100




pH 0 - 14
921 11 range : 0-1-2-3-4-5-6-7-8-9-10-11-12-13-14 100




pH 0.0 – 6.0
921 15 range : 0-0.5-1.0-1.5-2.0-2.5-3.0-3.5-4.0-4.5-5.0-5.5-6.0 100




pH 2.0 – 9.0
921 18 range : 2.0-2.5-3.0-3.5-4.0-4.5-5.0-5.5-6.0-6.5-7.0-7.5- 100

8.0-8.5-9.0




pH 4.5 – 10.0
921 20
100

range : 4.5-5.0-5.5-6.0-6.5-7.0-7.5-8.0-8.5-9.0-9.5-10.0




pH 6.0 – 10.0
921 22 range : 6.0-6.4-6.7-7.0-7.3-7.6-7.9-8.2-8.4-8.6-8.8-9.1- 100

9.5-10.0







pH 7.0 – 14.0
921 25 range : 7.0-7.5-8.0-8.5-9.0-9.5-10.-10.5-11.0-11.5-12.0- 100

12.5-13.0-13.5-14.0




pH 0.3 – 2.3
921 80 range : 0.3-0.7-1.0-1.3-1.6-1.9-2.3 100




pH 1.7 – 3.8
921 90 range : 1.7-2.0-2.3-2.6-2.9-3.2-3.5-3.8 100




pH 3.6 – 6.1
921 30 range : 3.6-4.1-4.4-4.7-5.0-5.3-5.6-6.1 100




pH 5.1 – 7.2
921 40 range : 5.1-5.4-5.7-6.0-6.3-6.6-6.9-7.2 100




pH 6.0 – 7.7
921 50 range : 6.0-6.4-6.7-7.0-7.3-7.7 100




pH 7.5 – 9.5
921 60 range : 7.5-7.9-8.2-8.4-8.6-8.8-9.1-9.5 100




pH 7.9 – 9.8
921 70 range : 7.9-8.3-8.6-8.9-9.1-9.4-9.8 100



Plastic box containing 100 strips 6 x 85 mm









PORTABLE MULTIPARAMETER PHOTOMETER






-     Field and laboratory use
-     Battery and mains operable
-     More than 100 preprogrammed calibration
-     Backlit graphic display with intuitive user guidance
-     Data storage according to GLP
-     USB interface for data transfer, update and power supply
-     Documentation of results according to GLP
-     Internal quality control according to ISO 9001
-     Fast photometer update – free of charge
-     Complete water and waste water analysis
-    Works under any condition






Model : Photometer PF-12 Plus






Type                : Filter photometer with microprocessor control, self-test and auto calibration,  Wavelength 340-860 nm
Optics             : Automatic filter wheel with 7 interference filters , Insensitive
to external light – no light shield required
Wavelengths    : 380/436/470/540/585/620/690 nm
Light source    : Tungsten lamp Detector          : Silicon photodiode Black value      : Automatic
Meas. mode     : over 100 preprogrammed tests (NANOCOLOR tube tests and
VISOCOLOR ECO tests)
Display            : Backlit graphic display, 64 x 128 pixels
Operation        : Display user guidance, plastic foil keyboard
Test Selection via test number of parameter lists.
12 languages (de,en,fr,es,it,ni,hu,pl,pt,cz,id,si) Interface         : USB 2.0
Ope. range      :  0-500C, up to 90 % relative humidity
Power supply   : via USB power supply, standard or rechargeable batteries) Dimensions      : 215 x 100 x 65 mm
Weight            : 0.7 kg






919 250 Photometer PF – 12 Plus

Complete with :

Software DVD, manual, 4 batteries, 4 empty test tubes, funnels, beaker, on equested

syringe,USB cable, calibration cuvette and certificate in rugged case



VISOCOLOR TESTS, which can be evaluated with PHOTOMETER PF-12



VISOCOLOR ECO Test Kits

Ammonium 3
931 208
50

range : 0.1 - 1.2 mg/l /NH -N   0.1-1.5 mg/l  NH + / NH

4                                                4             3




Ammonium 15
931 210
50

range : 0.1 - 1.2 mg/l /NH -N   0.1-1.5 mg/l  NH + / NH

4                                                4             3




Chloride
931 218 range : 1 - 40 mg/l Cl2 90




Chlorine 2 (free /total)
931 215 range : 0.1 - 2.0 mg/l Cl2 150




Free Chlorine 2
931 216 Range : 0.1 - 2.0 mg/l Cl2 150




Chlorine 6 (free and total)
931 217 Range :  0.05 – 6.00 mg/l Cl2 200




Free chlorine 6
931 219 Range :  0.05 – 6.00 mg/l Cl2 400




Chromium
931 220 Range : 0.02 - 0.50  mg/l / Cr(VI) 140

0.04 – 1.00 mg/l CrO 2-

4




Copper
931 237 Range : 0.2 - 1.5 mg/l /Cu 100




Cyanide
931 222 Range : 0.01 - 0.20  mg/l CN- 100




Cyanuric Acid
931 223 Range : 10 - 100 mg/l Cya 100




Fluoride
931 227 Range : 0.1 - 2.0 mg/l F- 150




Hydrazine
931 230 Range : 0.05 – 0.40 mg/l N2H4 130




Iron
931 226 Range : 0.04 - 1.00 mg/l Fe 100




Manganese
931 238 Range : 0.1 – 1.5 mg/l Mn 70




Nickel
931 240 Range : 0.1 - 1.5 mg/l Ni2+ 150




Nitrate
931 241 Range : 1 - 27 mg/l NO -N 4 – 120 mg/l NO- - 110

3                                              3




Nitrite
931 244 Range : 0.01 - 0.15 mg/l NO -N 0.02 – 0.50 mg/l NO- - 120

2                                                       2




Oxygen
931 288 range : 1 - 10 mg/l O2 50




PH
931 270 range : 6.0 – 8.2 pH 150




Phospate
931 284
80

range : 0.2 - 5.0 mg/l PO -P           0.6 – 15.0 mg/l PO 3-

4                                                                 4




Potassium
931 232 range :  2 – 15 mg/l K+ 60




Silica
931 233 range :  0.1 – 1.4 mg/l Si      0.2 - 3.0 mg/l SiO2 100




Sulphide
931 294 range :  0.05 - 0.80 mg/l S2- 90




Zinc
931 298 range : 0.1 - 3.0 mg/l Zn2- 120



NANOCOLOR®  tube Test

Aluminium
985 098 range : 0.02 - 0.70 mh/l Al3+ 20




Ammonium 3
985 003 range : 0.04 - 2.30 mg/l NH4-N 20

0.05 – 3.00 mg/l NH +/NH

4           3




Ammonium 10
985 004 range : 0.2 - 8.0 mg/l NH -N  0.2 – 10.0 mg/l NH +/NH 20

4                                                   4           3

Ammonium 50
985 005 range : 1 - 40 mg/l NH -N 1 – 50 mg/l  NH +/NH 20

4                                           4           3




Ammonium 100
985 005 range : 1 - 40 mg/l NH -N 1 – 50 mg/l  NH +/NH 20

4                                           4           3




Ammonium 200
985 006 range : 30 - 160 mg/l NH -N 0 – 200 mg/l NH +/NH 20

4                                            4           3




AOX 3
985 007 range : 0.01 - 3.0 mg/l AOX 20




BOD5 (Biochemical Oxygen Demand)
985 822 range :0.5 - 12.0 mg/l O2 2 – 3000 mg/l O2 25-50




BOD5-TT
985 825 range : 0.5 - 7.0 mg/l O2 2 – 3000 mg/l O2 Nop-21




Cadmium 2
985 014 range : 0.10 - 2.00 mg/l Cd2+ Okt-19




Carbonate hardness 15
985 015 range : 1.0 - 15.0 0d 0.4 – 5.4 mmol/l H+ 20




Chloride 50
985 021 range : 0.5 – 50 mg/l Cl- 20




Chloride 200
985 019 range : 5 - 200 mg/l Cl- 20




Chlorine / Ozone 2
985 017 range : 0.05 - 2.50 mol/Cl2 0.05 – 2.00 mg/l O2 20




Chlorine Dioxide 5
985 018 range : 0.2 - 5.0 mg/l Cl O2 20




Chromate 5
985 024 range : 0.03 - 1.80 mg/l Cr(VI) 0.1 – 4.0 mg/l CrO 2- 20

4




COD 40
985 027 range : 2 – 40 mg/l O2 20




COD 60
985 022 range : 5 – 60 mg/l O2 20







COD 160
985 026 range : 15 – 160 mg/l O2 20




COD 300
985 033 range : 50 – 300 mg/l O2 20




COD 1500
985 029 range : 100 - 1500 mg/l O2 20




COD 10000
985 023 range : 1.00 - 10.00 g/l O2 20




COD 15000
985 028 range : 1.0 – 15.0 g/O2 20




COD 60000
985 012 range : 1.0 – 15.0 g/O2 20




Org. Complexing agents 10
985 052 range :  0.5 – 10.0 mg/l IBIC Okt-19




Copper 7
985 054 range : 0.1 - 7.0  mg/l Cu2+ 20




Cyanide 08
985 031 range :  0.01 - 0.80 mg/l CN- 20




DEHA 1 (diethylhydroxylamine)
985 035 range :  0.05 - 1.00 mg/l DEHA 20




Ethanol 1000
985 838 range : 0.10 – 1.0 g/l EtOH    0.013 – 0.130 Vol % EtUH 23




Fluoride 2
985 040 range : 0.1 - 2.0 mg/l F- 20




Formaldehyde 8
985 041 range : 0.1 – 8.0 mg/l HCHO 20




Formaldehyde 10
985 046 range : 0.20 – 10.00 mg/l HCHO 20




Hardness 20
985 043 range : 1.0 – 20.0 0d  5 – 50 mg/l Mg2+ 20

range : 0.2 - 3.6 mmol/l  10 – 50 mg/l Ca2+




HC 300 (hydrocarbons)
985 057 range :  0.5 - 5.6 mg/l HC 30 – 300 mg/kg HC 20




Iron 3
985 037 range :  0.1 - 3.0 mg/l Fe 20




Lead 5
985 009 range : 0.1 - 5.0 mg/l Pb2+ 20




Manganese 10
985 058 range : 0.1 - 10.0 mg/l Mn 20




Methanol 15
985 859 range : 0.2 – 15.0 mg/l Me OH 23




Molybdenum 40
985 056 range : 1.0 -20.0 mg/l Mo(VI)    1.6 – 32.0 mg/l MoO 2- 20

4




Nickel 7
985 061 range : 0.1 - 7.0 mg/l Ni2+ 20




Nitrate 8
985 065 range : 0.30 - 8.00 mg/l NO -N 1.3 – 35.0 mg/l NO - 20

3                                                  2




Nitrate 50
985 064 range : 0.5 - 16.0 mg/l NO -N 0.03 – 1.50 mg/l NO - 20

3                                                     2




Nitrate 250
985 066 range : 4 - 60 mg/l NO -N   20 – 250 mg/l NO - 20`

3                                                  2




Nitrite 2
985 068 range : 0.01 - 0.45 mg/l / NO2-N 2 – 70 mg/l  NO3 20




Nitrite 4
985 069 range : 0.1 – 4.0 mg/l NO -N 0.3 – 13.0  mg/l  NO - 20

2                                                     2




Total Nitrogen 22
985 083 range : 0.5 - 16.0 mg/N 20




Total Nitrogen 220
985 088 range : 5 - 160 mg/N 20




Organic acids 3000
985 050 range : 30 - 3000 mg/ CH3COOH 20




Oxygen 12
985 082 range : 0.5 -12.0 mg/l O2 22




Peroxide 2
985 871 range : 0.1 -2.0 mg/l H2O2 Okt-19




pH
918 72 range :  6.5 - 8.2 pH 100




Phenolic Index 5
985 074 range : 0.2 - 5.0 mg/l 20




Potassium 50
985 045 range :  2 – 50 mg/l K+ 20




Ortho and total phospate 1
985 076 range : 0.1 - 1.5 mg/l PO4-P 0.2 – 5.0 mg/l PO 3- 19

4




Ortho and total Phospate 5
985 081 range : 0.2 - 5.0 mg/l PO4-P 0.5 – 15.0 mg/l PO 3- 19

4




Ortho and total Phospate 15
985 080 range : 0.3 - 15.0 mg/l PO -P 1.0 – 45.0 mg/l PO 3- 19

4                                                 4




Ortho and total Phospate 45
985 055 range : 5.0 - 50.0 mg/l PO -P 15 – 150 mg/l PO 3- 19

4                                              4




Ortho and total phospate 50
985 079 range : 10.0 - 50.0 mg/l PO -P 30 – 150 mg/l PO 3- 19

4                                              4




POC 200 (polyoxycarboxylic acid)
985 070 range : 20 – 120 mg/l 2 – 40 mg/l 20




Residual Hardness 1
985 084 range : 0.05 - 1.00 0d     0.009 – 0.18 mmol/l 20




Silver 3
985 049 range : 0.20 – 3.00 0d     0.009 – 0.18 mmol/l 20




Strach 100
985 085 range : 5 – 100 mg/l 19




Sulphate 200
985 086 range : 10 – 200 mg/l SO 2- 20

4




Sulphate 1000
985 087 range : 200 – 1000 Mg/l SO 2-- 20

4




Sulphite 3
985 073 range :  0.05 – 3.00 mg/l S2- 20




Sulphite 10
985 089 range :  0.2 - 10.0 mg/l SO 2- 20




Sulphite 100
985 090 range : 5 – 100 mg/l SO32- 19




Surfactants, anionic surfactants 4
985 032 range : 0.20 – 4.00 mg/l MBAS 20




Surfactants, Cationic surfactants 4
985 034 range : 0.20 – 4.00 mg/l CTAB 20




Surfactants, Nonionic surfactants 15
985 047 range : 0.3 – 15.00 mg/l Triton X-100 20




Thiocyanate 50
985 091 range : 1.0 - 50.0 mg/l SCN- 20




Tin 3
985 097 range : 0.1 - 3.0 mg/l Sn 18




TOC 25 (Total Organic Carbon)
985 093 range : 2.0 – 25.0 mg/l TOC 10




TOC 60 (Total Organic Carbon)
985 094 range : 10 – 60 mg/l TOC 10




TOC 600 (Total Organic Carbon)
985 099 range : 40 – 600 mg/l TOC 10




TTC / Sludge activity 150
985 890 5 – 150 ug TPF 20

0.050 – 2.300 E




Zinc 4
985 096 range : 0.1 - 4.0  mg/l Zn2+ 20









PROGRAMMABLE HEATING BLOCK for SAMPLE DIGESTION Model : Vario C2
Constant digestion conditions
  High temperature stability
  Electronic overheating protection
  Graphic display of heating curves






Maximum safety for the user
  Extra strong safety covers as contact
protection (10 mm, replaceable)
on the heating block surface
  Lockable protective lids
  Display alert in case of open protective lid






Instrument:  NANOCOLOR ® VARIO C2
Programmable heating blocks for chemical-analytical digestions



Type:




with 12 holes / for test tubes with 16 mm OD (outer diameter) /
integrated protective lids



Display:         Coloured, backlit LCD touch screen
Operation:     Display menu guidance via touch screen



Temperature 5 pre-programmed temperatures: 70 / 100 / 120 / 148 / 160 °C
s:                   7 free memory locations for individual temperature settings
Temperature 40 – 160 °C (1 °C increments)
range:

Temperature ± 1 °C (according to DIN, EN, ISO and EPA methods)
stability:




Warm-up

time: Heating

times:




from 20 °C to 160 °C within 10 minutes



4 pre-programmed heating times: 30 min / 60 min / 120 min /
cont.

8 free memory locations for individual heating times



Time range:  0h:01min – 9h:59min (increments 0h:01min)
Replaceable safety covers as contact protection



Safety:




Lockable protective lids
Overheating protection



Interfaces:    Bidirectional serial RS 232, USB A (master) and USB B (slave)






Analytical quality control:



 Wi th  N A N OC OLOR®  T-Set  (REF  919  917) 
optional fully automatic calibration and preparation of test certificates for instrument control and monitoring according to ISO
9001)

Update:         Via internet and USB stick
Power supply:
Power

110 – 230 V~, 50/60 Hz
consumption 125/250 VA
Dimensions 169 x 282 x 146 mm
(B x T x H)

Weight:         approx. 2.0 kg
Marking:        CE
Warranty:      2 years
Suitable for all NANOCOLOR ® digestion methods
Application                                           Temperatur e
Time




COD (DIN ISO 15705)                                       148 °C            120 min
High-speed COD                                           160 °C             30 min
TOC                                                    120 °C            120 min total-Nitrogen                                             120 °C             30 min
total-Phosphorous                                          120 °C             30 min
Organic acids                                             100 °C             10 min



total-Metals (Cadmium, Chromate, Iron, Cobalt, Copper, Nickel, Zinc)



120 °C             30 min



AOX                                                    120 °C             30 min
Hydrocarbons                                             148 °C            120 min
Programmable, user-defined programs                        40 - 160 °C       0h:01min -
9h:59min







919 350     NANOCOLOR ® VARIO C2
Heating block incl. protective lids, power line cord, USB cable,
software-DVD, certificate and manual                                                                    on requested









MULTIPARAMETER PHOTOMETER






-     Field and laboratory use
-     Suitable for universal use in water and wastewater analysis
- Illuminated graphic display with use guidance shows all the important data at a glance
-     Automatic storage can be switched on and off in the configuration menu
-     Easy updating and data processing
-     NANOCOLOR Bar Code Technology (NBT)
-     Universal cuvette holder









Model : Photometer NANOCOLOR 500 D






Type                          : single beam filter photometer with microprocessor control, self
test and auto calibration, wavelength range 340-860 nm Optics                       : automatic filter wheel with 10 interference filters Wavelengths              : 345/365/436/470/520/540/585/620/690/800 nm
plus 2 compartments for additional filters wavelength accuracy  : ± 2 nm, bandwidth at half transmission 10-12 nm Light source               : Tungsten lamp
Detector                    : Silicon photodiode
Blank value                : automatic and prestored
Measuring mode        : over 100 preprogrammed tests, 99 freely programmable
methods, extinction, transmission, factor, kinetics, two-point calibration
Measuring range        :  about 3 E neutral sign
Photometric accuracy : ± 1 % Stability                     : < 0.002 E/h
Cuvette holder           :  round tubes 16 mm, rectangular cuvettes 10,20,50 mm
Data Memory             : 500 measurement data records, GLP compatible
Display                      : graphic display,backlight, 64x128 pixels, 10 languages
Operation                  : bar code technology, display user guidance, foil-coveredpush-buttons
Interfaces                  : USB 1.1 and bi-directional serial RS232
Update                      : via internet / PC
Operating range         : 0-50 0C, up to 90% relative humidity
Power supply             : 100-240V,50/60 Hz / 6V. 3.2 Ah via built-in battery with charge regulator and
Dimensions               : 227 x 282 x 105 mm









919 500 PHOTOMETER NANOCOLOR 500 D

Complete with : on requested

Software CD, manual dust cover, mains power supply, data cable, USAB cable,

and calibration cuvette in stable transport bag









NANOCOLOR®  tests, which can be evaluated with PHOTOMETER 500D






NANOCOLOR®  tube Test 

Aluminium
985 098 range : 0.02 - 0.70 mh/l Al3+ 20




Ammonium 3
985 003 range : 0.04 - 2.30 mg/l NH -N 0.05 – 3.00 mg/l NH +/NH 20

4                                                    4           3




Ammonium 10
985 004 range : 0.2 - 8.0 mg/l NH -N 0.2 – 10.0 mg/l NH +/NH 20

4                                                 4           3




Ammonium 50
985 005 range : 1 - 40 mg/l NH -N 1 – 50 mg/l  NH +/NH 20

4                                          4           3




Ammonium 200
985 006 range : 30 - 160 mg/l NH -N 40 – 200 mg/l NH +/NH 20

4                                              4           3




AOX 3
985 007 range : 0.01 - 3.0 mg/l AOX 20




BOD5 (Biochemical  Oxygen Demand)
985 822 range :0.5 - 12.0 mg/l O2 2 – 3000 mg/l O2 25-50




BOD5-TT
985 825 range : 0.5 - 7.0 mg/l O2 2 – 3000 mg/l O2 Nop-21




Cadmium 2
985 014 range : 0.10 - 2.00 mg/l Cd2+ Okt-19




Carbonate hardness 15
985 015 range : 1.0 - 15.0 0d 0.4 – 5.4 mmol/l H+ 20




Chloride 50
985 021 range : 0.5 - 50 mg/l Cl- 20




Chloride 200
985 019 range : 5 - 200 mg/l Cl- 20




Chlorine / Ozone 2
985 017 range : 0.05 - 2.50 mol/Cl2 0.05 – 2.00 mg/l O2 20







Chlorine Dioxide 5
985 018 range : 0.2 - 5.0 mg/l Cl O2 20




Chromate 5
985 024 range : 0.03 - 1.80 mg/l Cr(VI) 0.1 – 4.0 mg/l CrO 2- 20

4




COD 40
985 027 range : 2 - 40 mg/l O2 20




COD 60
985 026 range : 5 - 60 mg/l O2 20




COD 160
985 022 range : 15 - 160 mg/l O2 20




COD 300
985 033 range : 50 - 300 mg/l O2 20




COD 1500
985 029 range : 100 - 1500 mg/l O2 20




COD 10000
985 023 range : 1.00 - 10.00 g/l O2 20




COD 15000
985 028 range : 1.0 - 15.0 g/O2 20




Colour

range : 10 - 500 mg/l                          (no reagents required)




Org. Complexing agents 10
985 052 range :  0.5 - 10.0 mg/l IBIC Okt-19




Copper 7
985 054 range : 0.1 - 7.0  mg/l Cu2+ 20




Cyanide 08
985 031 range : 0.01 - 0.80 mg/l CN- 20




DEHA 1 (diethylhydroxylamine)
985 035 range :  0.05 - 1.00 mg/l DEHA 20




Ethanol 1000
985 838 range : 0.10 – 1.0 g/l EtOH 0.013 – 0.130 Vol % EtUH 23




Extinction

range : 0.010 – 2500 E (no reagents required)

Fluoride 2
985 040 range : 0.1 - 2.0 mg/l F- 20




Formaldehyde
985 041 range : 0.1 - 8.0 mg/l HCHO 20




Hardness 20

range : 1.0 - 20.0 0d  5 – 50 mg/l Mg2+
985 043 range : 0.2 - 3.6 mmol/l  10 – 50 mg/l Ca2+ 20




Residual Hardness
985 084 range : 0.02 – 1.00 0d 0.004 – 0.180 mmol / 20




HC 300 (hydrocarbons)
985 057 range :  0.5 - 5.6 mg/l HC 30 – 300 mg/kg HC 20




Iron 3
985 037 range :  0.1 - 3.0 mg/l Fe 20




Leads
985 009 range : 0.1 - 5.0 mg/l Pb2+ 20




Manganese 10
985 058 range : 0.1 - 10.0 mg/l Mn 20




Methanol 15
985 859 Range : 0.2 - 15.0 mg/l Me OH 23




Molybdenum 40
985 056 range : 1.0 -20.0 mg/l Mo(VI) 1.6 – 32.0 mg/l MoO 2- 20

4




Nickel 7
985 061 range : 0.1 - 7.0 mg/l Ni2+ 20




Nitrate 50
985 064 range : 0.5 - 16.0 mg/l NO -N 0.03 – 1.50 mg/l NO - 20

3                                                    2




Nitrite 2
985 068 range : 0.01 - 0.45 mg/l / NO2-N 2 – 70 mg/l  NO3 20




Nitrite 4
985 069 Range : 0.1 – 4.0 mg/l NO -N 0.3 – 13.0  mg/l  NO - 20

2                                                     2




Total Nitrogen 22
985 083 range : 0.5 - 16.0 mg/N 20

Total Nitrogen 220
985 088 range : 5 - 160 mg/N 20




Oxygen 12
985 050 Range : 0.5 – 12.0 mg/l O2 12




Peroxide
985 871 range : 0.1 -2.0 mg/l H2O2 Okt-19




pH
918 72 range :  6.5 - 8.2 pH 100




Phenolic Index 5
985 074 range : 0.2 - 5.0 mg/l 20




Ortho and total phospate 1
985 076 range : 0.1 - 1.5 mg/l PO4-P 0.2 – 5.0 mg/l PO 3- 19

4




Ortho and total Phospate 5
985 081 range : 0.2 - 5.0 mg/l PO4-P 0.5 – 15.0 mg/l PO 3- 19

4




Ortho and total Phospate 15
985 080 range : 0.3 - 15.0 mg/l PO -P 1.0 – 45.0 mg/l PO 3- 19

4                                                 4




Ortho and total Phospate 45
985 055 range : 5.0 - 50.0 mg/l PO -P 15 – 150 mg/l PO 3- 19

4                                             4




Ortho and total phospate 50
985 079 range : 10.0 - 50.0 mg/l PO -P 30 – 150 mg/l PO 3- 19

4                                             4




POC 200 (polyoxycarboxylic acid)
985 070 range : 20 – 120 mg/l 2 – 40 mg/l 20




Potassium 50
985 045 range : 2 - 50 mg/ K+ 20




Oxygen 12
985 082 range : 0.5 – 12.0 mg/l O2 22




Strach 100
985 085 range : 5 - 100 mg/l 19




Sulphate 200
985 086 range : 10 - 200 mg/l SO 2- 20

4

Sulphate 1000
985 087 range : 200 - 1000 Mg/l SO 2-- 20

4




Sulphite 10
985 089 range :  0.2 - 10.0 mg/l SO 2- 20

3




Sulphite 100
985 090 range : 5 - 100 mg/l SO 2- 19

3




Nonionic surfactants 15
985 047 range : 0.3 – 15.0 mg/l triton X-100 20




Thiocyanate 50
985 091 range : 1.0 - 50.0 mg/l SCN- 20




Tin 3
985 097 range : 0.1 - 3.0 mg/l Sn 18




TOC 70 (Total Organic Carbon)
985 094 range : 2 - 70 mg/l C 20




TTC / slugde activity 150
985 890 range : 5 – 150 mg TPF 20




Zinc 4
985 096 range : 0.1 - 4.0  mg/l Zn2+ 20
NANOCOLOR®  tests, which can be evaluated with PHOTOMETER 500D NANOCOLOR STANDARD TESTS

Ammonium
918 05 range : 0.01 – 2.0 mg/l NH -N     0.01- 2.5 mg/l NH4+ (690 nm) 100

4




Chloride
918 20 range : 0.02 – 10.0 mg/l Cl(470 nm) 220




Chlorine
918 16 range : 0.02 – 10.0 mg/l Cl2 (540 nm) 250




Chlorine Dioxide
918 163 range : 0.04 – 4.00 mg/l ClO2 (540 nm) 50

Chromate
918 25 range : 0.01 – 3.0 mg/l Cr(VI)    0.01–6.0 mg/l CrO  2- (540 nm) 250

4




Cobalt
918 51 range : 0.002 – 0.70 mg/l Co2+ (540 nm) 220




Colour (Hazen / DIN)

range : 5 – 500 mg/l Pt Hazen      0.2 – 20.01/m  (436 nm)




Copper
918 53 range : 0.01 – 10.0 mg/l Cu2+ (585 nm) 250




Cyanide
918 30 range : 0.001 –0.50 mg/l CN- (585 nm) 250




Fluoride
918 142 range : 0.05 – 2.0 mg/l F- (585 nm) 200




Hydrazine
918 44 range : 0.002 – 1.50 mg/l N2H2 (436 nm) 220




Iron
918 36 range : 0.01 – 15.0 mg/l Fe (470 nm) 250




Manganese
918 60 range : 0.01 – 10.0 mg/l Mn (470 nm) 250




Nickel
918 62 range : 0.01 –10.0 mg/l Ni2+ (436 nm) 250




Nitrate



918 65 range : 0.9 – 30.0 mg/l NO  N     2 – 140 mg/l NO -   (365/385 nm) 250

3                                                 3




Nitrate Z
918 63 range : 0.02 – 1.0 mg/l NO  N     0.1 – 5.0 mg/l NO -    (520 nm) 100

3                                                     3




Nitrite



918 67 range : 0.02 – 0.03 mg/l NO - N    0.05– 1.00 mg/l NO - (520 nm) 220

2                                                         2




Phenol
918 75 range : 0.01 – 7.0 mg/l Phenol      (470 nm) 440







Ortho- Phosphate
918 77 range : 0.04 – 6.5 mg/l PO P     0.1 – 20 mg/l PO 3- (690 nm) 440

4                                                 4




Ortho- Phosphate
918 78 range : 0.2 – 17 mg/l PO P     0.5 – 50 mg/l PO 3- (436 nm) 440

4                                                 4




Silica

range : 0.01 – 5.00 mg/l Si    0.02 – 10.0 mg/l SiO2 (690 nm)
918 48 0.002 – 0.100 mg/l S-      0.005-0.200 mg.l Si O 3   (800 nm) 250

2




Sulphide
918 88 range : 0.01 – 3.0 mg/l S2-         (620/660 nm) 250




Turbidity (formazine/DIN)

range : 1 – 100 TE/F (=FAU)      (620/860 nm)




Zinc
918 95 range : 0.02 – 3 mg/l Zn2+ (620 nm) 250

Tidak ada komentar: