1) COLORI METER 
   TYPE : SMART 3 
    Merk : LAMOTTE

 

 

 

Specification:
The user-friendly SMART3 Colorimeter is the ideal direct reading colorimeter for complete on-site water analyses.

The compact SMART3 Colorimeter is ideal for water analysis in the field or in the lab. Easy to use software allows the analyst to choose a test factor from over 75 preprogrammed calibrations for LaMotte reagent systems. The reacted sample is always scanned at the optimum wavelength which is automatically selected from the multiple LED optical system and the test result is presented on the large, backlit display. The test result is displayed directly in units of concentration, as well as Absorbance and % T, in one of seven languages. The analyst also has the option of entering up to 25 additional calibrations for analysis with custom reagent systems. Test factors can be arranged in any of three sequences that can be modified at any time to meet changing testing needs. The data logger holds up to 500 time and date stamped data points. A USB connection allows an interface of the colorimeter with a computer for real-time data acquisition and data transfer. The meter logs up to 500 data points.

Features Include: ï ¿ ½
# IP67 Waterproof
# Large graphical liquid crystal display
# Simple, menu-driven operation
# Alphabetical test selection
# Pre-programmed tests
# Lithium ion rechargeable battery or computer/ wall adapter
# Data logger for 500 data points
# 25 User tests
# Backlit display
# Auto-off
# USB port
# European CE mark

Additional Advancements include: ï ¿ ½
# Superior narrow band-width interference filters
# Super Twist Backlit LCD display for improved readability
# Optional software for data storage and manipulation

Specifications

Readout: 160 x 100 backlit LCD, 20 x 6 line graphical display
Wavelengths: 428 nm, 525 nm, 568 nm, 635 nm
Wavelength Accuracy: ï ¿ ½ 2% FS
Wavelength Bandwidth: 10 nm typical
Photometric Range: -2 to + 2 AU
Photometric Precision: ï ¿ ½ 0.001 AU at 1.0 AU
Photometric Accuracy: ï ¿ ½ 0.005 AU at 1.0 AU
Light Sources: 4 LEDs
Detectors: 4 silicon photodiodes with integrated interference filters
Modes: Pre-programmed tests, absorbance, % T
Languages: English, Spanish, French, Portuguese, Italian, Chinese, Japanese
Sample Chamber: 25 mm diameter flat bottom test tubes, 10 mm square cuvettes, 16 mm COD tubes
USB Port: Mini B
Power: Lithium ion rechargeable battery, 3.7v, 2.5 x .75 inches, 1.7 oz. or USB computer cable or wall adapter
Battery: Charge Life: Approx. 380 tests with backlight on to 1000 tests with backlight off. ( Singnal averaging disabled) .
Battery Life: Approx. 500 charges
Auto Shut-off: Disabled, 5, 10, 50 minutes
Dimensions: 8.84 x 19.05 x 6.35 cm; 3.5 x 7.5 x 2.5 inches
Weight: 362 g; 13 ounces
Ship Dimensions: 29.2 x 27.9 x 11.43 cm; 11.5 x 11 x 4.5 inches
Ship Weight: 1.18 kg; 4 lbs.

================================================

2)  Portable Colorimeter
    Merk : HACH 
    Model :  DR890 / 48470-00

  

 

Specification : 
HACH DR/ 820 DR/ 850 DR/ 890 • Tests for 50+ methods.
• DR/ 820Tests for 20+ methods
• DR/ 850 Tests for 50+ methods
• DR/ 890Tests for 90+ methods

Aluminum, Aluminon 0 - 0.8 • • •
Benzotriazole 0 - 16 •
Bromine 0 - 4.50 • • •
Bromine ( AccuVac® ) 0 - 4.50 • • •
Chlorine, Free, HR 0 - 10.0 • • •
Chlorine, Free ( USEPA) 0 - 2.00 • • •
Chlorine, Free ( AccuVac) ( USEPA) 0 - 2.00 • • •
Chlorine, Free, TNT 0 - 5.00 • • •
Chlorine, Total, HR 0 - 10.0 • • •
Chlorine, Total ( USEPA) 0 - 2.00 • • •
Chlorine, Total ( AccuVac) ( USEPA) 0 - 2.00 • • •
Chlorine, Total, TNT 0 - 5.00 • • •
Chlorine Dioxide, MR 0 - 50 •
Chromium, Hexavalent ( USEPA) 0 - 0.60 •
Chromium, Hexavalent ( AccuVac) ( USEPA) 0 - 0.60 •
Chromium, Total 0 - 0.60 •
Color, True and Apparent 0 - 500 •
Copper, Bicinchoninate ( USEPA) * * 0 - 5.0 •
Copper, Bicinchoninate ( AccuVac) ( USEPA) * * 0 - 5.0 •
Copper, Porphyrin, LR 0 - 210 µ g/ L •
Cyanide 0 - 0.240 • •
Cyanuric Acid 7 - 55 • • •
DEHA 0 - 500 µ g/ L •
Detergents ( Surfactants) 0 - 0.30 • •
Fluoride, SPADNS* * * 0 - 2.0 • •
Fluoride, SPADNS ( AccuVac) * * * 0 - 2.0 • •
Hardness, Calcium as CaCO3 0 - 4.0 • • •
Hardness, Magnesium as CaCO3 0 - 4.0 • • •
Hydrazine 0 - 500 µ g/ L •
Hydrazine ( AccuVac) 0 - 500 µ g/ L •
Iron, Ferrous 0 - 3.0 • • •
Iron, Ferrous ( AccuVac) 0 - 3.0 • • •
Iron, Total, FerroMo™ 0 - 1.8 • •
Iron, Total, FerroVer® ( USEPA) * * 0 - 3.0 • • •
Iron, Total, FerroVer ( AccuVac) ( USEPA) * * 0 - 3.0 • • •
Iron, Total, FerroZine® 0 - 1.3 •
Iron, Total, TPTZ 0 - 1.8 • •
Iron, Total, TPTZ ( AccuVac) 0 - 1.8 • •
Manganese, HR ( USEPA) * * 0 - 20 • • •
Manganese, LR 0 - 0.70 •
Molybdenum, Molybdate, HR 0 - 40 •
Molybdenum, Molybdate, HR ( AccuVac) 0 - 40 •
Molybdenum, Ternary Complex, LR 0 - 3.0 • •
Nickel, PAN 0 - 1.0 •
Nitrate, Cadmium Reduction, HR 0 - 30 • • •
Nitrate, Cadmium Reduction, HR ( AccuVac) 0 - 30 • • •
Nitrate, Cadmium Reduction, MR 0 - 5.0 •
Nitrate, Cadmium Reduction, MR ( AccuVac) 0 - 5.0 •
Nitrate, Cadmium Reduction, LR 0 - 0.50 • • •
Nitrate, Chromotropic Acid, HR, TNT 0 - 30 •
Nitrite, HR 0 - 150 •
Nitrite, LR ( USEPA) 0 - 0.35 • • •
Nitrite, LR ( AccuVac) ( USEPA) 0 - 0.35 • • •
Nitrite, TNT 0 - 0.50 • • •
Nitrogen, Ammonia, Salicylate 0 - 0.50 • •
Nitrogen, Ammonia, LR, TNT 0 - 2.50 • •
Nitrogen, Ammonia, HR, TNT 0 - 50 • •
Nitrogen, Monochloramine and Free Ammonia, Salicylate 0 - 0.50 • •
Nitrogen, Monochloramine and Free Ammonia, Salicylate ( AccuVac) 0 - 0.50 • •
Nitrogen, TKN with Nessler finish* * 0 - 150 •
Nitrogen, Total, Persulfate Digestion, TNT † 0 - 25 •
Nitrogen, Total, HR, TNT † 0 - 150 •
Nitrogen, Total Inorganic, TNT 0 - 25 • •
Oxygen, Dissolved, HR ( AccuVac) 0 - 15 • • •
Oxygen, Dissolved, LR ( AccuVac) 0 - 1000 µ g/ L • •
Oxygen Demand, Chemical, LR ( USEPA) † 0 - 150 •
Oxygen Demand, Chemical, HR ( USEPA) † 0 - 1500 • •
Oxygen Demand, Chemical, HR † 0 - 15, 000 • •
Oxygen Demand, Chemical, Manganese III † 20 - 1000 • • •
Ozone, LR ( AccuVac) 0 - 0.25 • •
Ozone, MR ( AccuVac) 0 - 0.75 • •
Ozone, HR ( AccuVac) 0 - 1.5 • •
pH 6.5 - 8.5 pH • • •
Phosphonates 0 - 125 • •
Phosphorus, Molybdovanadate 0 - 45 •
Phosphorus, Molybdovanadate ( AccuVac) 0 - 45 •
Phosphorus, PhosVer® 3 ( USEPA) 0 - 2.5 • •
Phosphorus, PhosVer 3 ( AccuVac) ( USEPA) 0 - 2.5 • •
Phosphorus, PhosVer 3, TNT ( USEPA) 0 - 5.0 • •
Phosphorus, Total, PhosVer 3, TNT ( USEPA) † 0 - 3.5 • •
Phosphorus, Acid Hydrolyzable, PhosVer 3, TNT 0 - 5.0 • •
Phosphorus, Amino Acid 0 - 30 • • •
Silica, UHR 0 - 200 •
Silica, HR 0 - 75.0 •
Silica, LR 0 - 1.6 • •
Sulfate ( USEPA) 0 - 70 • • •
Sulfate ( AccuVac) ( USEPA) 0 - 70 • • •
Sulfide ( USEPA) 0 - 0.7 • •
Suspended Solids 0 - 750 • •
Tannin and Lignin 0 - 9.0 • •
Tolyltriazole 0 - 15 •
Total Organic Carbon, HR † 100 - 700 • •
Total Organic Carbon, MR † 15 - 150 • •
Total Organic Carbon, LR † 0 - 20.0 • •
ToxTrak™ Toxicity % inhibition • •
Turbidity 1 - 1000 FAU • • •
Volatile Acids 0 - 2800 • • •
Zinc ( USEPA) * * 0 - 3.0 • •

Keterangan :
. Parameter Range DR/ 890
.. Parameter Range DR/ 850 dan DR/ 890

... Parameter Range DR/ 820 DR/ 850 dan DR/ 890 ..

================================================

3. Multiparameter Handheld Colorimeter 
   Type : DR900 
   Merk :HACH 



 



 

 

Specifications :
Battery Life: months ( typical) @ 5 readings a day / 5 days / week without backlight* * * * Backlight usage will decrease battery life.
Battery Requirements: 4, AA size alkali cells
Data Logger: 500 measured values ( Result, Date, Time, Sample ID, User ID)
Detector: Silicon photodiode
Dimensions ( H x W x D) : 9.1 in x 3.8 in x 1.9 in ( 231 mm x 96 mm x 48 mm)
Display: Graphical display 240 x 160 pixels ( Backlit)
Enclosure Rating: IP67 ( vial cover closed)
Includes: DR 900 Colorimeter, two 1-inch glass sample cells marked at 10, 20 and 25 mL, two 1 cm plastic sample cells, 1 x 16-mm COD/ Test ' N Tube™ adapter, 4 AA alkaline batteries, printed multilingual instrument manual, instrument and procedure manuals on CD, USB Mini to USB Cable, European CE mark.
Interface: USB type Mini IP67
Manual Languages: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Operating Conditions: 10 to 40° C ( 50 - 104 ° F) , max. 80 % relative humidity ( non- condensing)
Operating Humidity: max 90 % relative humidity ( non-condensing)
Operating Mode: Transmittance ( % ) , Absorbance and Concentration
Operating Temperature: 10 to 40 ° C
Optical System: 0 / 180 0 / 180 deg transmittance
Photometric Accuracy: ± 0.005 Abs @ 1.0 ABS Nominal
Photometric Linearity: ± 0.002 Abs ( 0 - 1 Abs)
Photometric Measuring Range: 0 to 2 Abs
Power supply: 4 x AA size alkaline cells 4x NiMH rechargeable Battery* ( * External charger required)
Reproducibility: ± 0.005 Abs ( 0 - 1 A)
Sample Cell Compatibility: 1 inch round or 16 mm round ( with adapter)
Source Lamp: Light Emitting Diode ( LED)
Spectral bandwidth: 15 nm filter bandwidth
Storage Conditions: -30 to 60 ° C ( -30 - 140 ° F) , max. 80 % relative humidity ( non-condensing)
Stray Light: < 1.0 % at 400 nm
Supported Chemistry: HACH tests
Temperature Range: 0 to 50 ° C ( 32 - 122 ° F)
User Interface Languages: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
User Programs: Custom programming 10
Wavelength Accuracy: ± 1 nm ( fixed, varies with model)
Wavelength Calibration: N/ A
Wavelength Range: 420 nm, 520 nm, 560 nm, 610 nm
Wavelength Selection: Automatic
Weight: 1.32 lbs. ( 0.6 kg) with battery 


========================================================================
4) Portable Colorimeter
    Type : DR820
    Merk : HACH  


 Specifications
Beam Height: 5 mm
Data Logger: 500 measured values ( result, date, time, sample ID, user ID according to GLP)
Display: LCD, shows results, parameter, name, and unit
Display Size: 38 mm x 64 mm ( 1.5 in x 2.5 in)
Display Type: monocromatic ( black)
Manual Languages: English, German, Italian
Operating Temperature: 10 to 40 ° C
Operating Temperature Range: 0 to 50 ° C
Optical System: 0 / 180 transmittance
Sample Cell Compatibility: 1 in and 16 mm round vial ( 16 mm with adapter)
Spectral bandwidth: 15 nm filter bandwidth
User Interface Languages: English
User Programs: 10 user entered programs, 12 data points each
Warranty: 1 year
Wavelength Accuracy: ± 1 nm Fixed Wavelength, varies with model
Wavelength Range: 520 nm
Wavelength Selection: Automatic based on test selected

  ===============================================

 5) Digital Colori Meter
     Type : AC-114
     Merk : Optima - Japan



Specification :
* Wavelenght Range : 400 to 700 nm

* Photometric Range :
- Transmittance: 0.0 - 150.0 % T
- Absorbance: 0.0 - 1.999 Abs
- Concertation: 0.0 - 1999 Conc.

* Display : 3 digit LCD ( T% / Abs/ COnc./ Factor)

* Detector : Silicon photo-diode
* Light Source : LED
* Filter : Interchangeable glass filter
( 420nm, 470nm, 530 nm, 620nm and 660nm

* Sample Volume : 1.0 ml ( minimal)
* Sample Container : Round ( ? 12mm) and square cuvette
* Electrical : 100-240 VAC, 50/ 60 Hz, Selected automatically
* Data Output : RS-232C Interface, printer ( optional)
* Dimension : 250( W) x 335( H) x 155( D) mm
* Net Weight : 2.2 kg 
 











.
.
.
..



"081362449440 Jual Colori meter"

"PORTABLE COLORI METER Smart3 LAMOTTE"

"PORTABLE COLORI METER

DR890 HACH"

"PORTABLE COLORI METER

DR820 HACH"

"PORTABLE COLORI METER

DR900 HACH"

"PORTABLE COLORI METER

AC114 OPTIMA - Japan"

"HARGA COLORI METER Rp..."

" COLORI METER INDONESIA "

1 komentar:

  1. My partner and i spend less some sort of contradict in order to orchestrate the most effective article in my class. I had run truant associated with insights simply acknowledges for your publish, My partner and i instantly seize how you can obtain the actual opposition. Admit an individual therefore lots for this! harga dock leveler

    BalasHapus