pH Meter Series
====================================
The measure of a liquid’s acidity
and alkalinity, pH is one of the most common
parameter measured in a wide variety of industries
ranging from water and wastewater treatment,
chemical production, agriculture research
and production, environmental monitoring,
chemical and life sciences research, biochemical
and pharmaceutical research, electronics production
to food processing and other industrial applications.
Eutech offers a wide range of
pH meters that measure pH values in various
educational, laboratory and industrial applications.
These include the pHTestr™10, 20 and 30 pocket
testers, portable meters CyberScan Series
pH 300, pH 310, pH 11 and pH 110, EcoScan
pH 6 and the CyberScan bench meter series
510, 1100, 2100, 1500 and the colour touchscreen
research-grade series 6000.
Browse by product type:
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Open pore, spear pH sensor |
pH |
-1.00 to 15.00 pH |
No |
|
0.1 resolution |
pH |
-1.0 to 15.0 pH |
No |
|
0.01 resolution |
pH |
-1.00 to 15.00 pH |
No |
|
Temp display |
pH, °C/°F |
-1.00 to 15.00 pH |
No |
|
BNC electrode connection |
pH |
-1.00 to 15.00 pH |
No |
|
±0.1 pH Accuracy |
pH |
0.0 to 14.0 pH |
No |
|
3-point calibration, ATC |
pH |
0.0 to 14.0 pH |
No |
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical pH measurement |
pH/°C |
0.00 to 14.00 pH |
No |
|
Economical pH, ORP measurement |
pH/mV/°C |
0.00 to 14.00 pH |
No |
|
Economical pH measurement |
pH/°C |
0.00 to 14.00 pH |
No |
|
Economical pH, ORP measurement |
pH/mV/°C |
0.00 to 14.00 pH |
No |
Standard Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Standard Handheld |
pH/mV/°C |
-2.00 to 16.00 pH |
50 data sets |
|
Expanded memory, RS232 output |
pH/mV/°C/°F |
-2.00 to 16.00 pH |
100 data sets |
Waterproof Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof Handheld |
pH/mV/°C/°F/Ion |
-2.000 to 19.999 pH |
500 data sets |
|
Waterproof Handheld |
pH/mV/°C/°F |
-2.000 to 19.999 pH |
500 data sets |
|
Waterproof Handheld |
pH/mV/°C/°F |
-2.00 to 19.99 pH |
500 data sets |
|
Waterproof Handheld |
pH/mV/Ion/°C/°F |
-2.00 to 16.00 pH |
500 data sets |
|
Waterproof Handheld |
pH/mV/°C |
-2.00 to 16.00 pH |
16 data sets |
|
Waterproof, GLP |
pH/mV/°C/°F |
-2.00 to 16.00 pH |
50 data sets |
|
Waterproof Handheld |
pH/mV/°C/°F |
-2.00 to 16.00 pH |
150 data sets |
Economy Bench / Standard Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Large LCD with dual display economy bench |
pH/ORP/ºC/ºF |
-2.00 to 16.00 pH |
100 data sets |
|
Dual display standard bench |
pH/mV/°C |
0.00 to 14.00 pH |
50 data sets |
Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Graphic LCD with backlight & extensive display |
pH/mV/°C/°F |
-2.000 to 20.000 pH |
500 data sets |
|
Back-lit dual- display |
pH/mV/°C/°F |
-1.000 to 14.000 pH |
100 data sets |
|
Back-lit dual- display Ion concentration measurement |
pH/mV/Ion/°C/°F |
-1.000 to 14.000 pH |
100 data sets |
Premium Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Extensive display |
pH/mV/°C/°F |
-1.999 to +19.999 pH |
100 data sets |
|
Windows® CE-driven single channel colour touchscreen (with pH FET) |
pH/mV/ °C/°F |
-2.000 to +20.000 pH |
10,000 data sets |
|
Windows® CE-driven dual channel colour touchscreen (with pH FET) |
pH/mV/Ion/ °C/°F |
-2.000 to +20.000 pH |
10,000 data sets |
Process Instruments |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Functions
|
1/8 DIN panel mount, 2 set points relays, Easy set point adjustment and direct CAL |
pH/mV/°C |
0.00 to 14.00 pH |
Limit Control |
|
1/8 DIN panel mount, 2 set points relays, Password protection for set point adjustment and calibration |
pH/mV/°C |
0.00 to 14.00 pH |
Limit Control |
|
2-wire transmitter, panel mount or wall mount, offset adjustment, 'out-of-range' and 'hold' indicators |
pH/mV/°C |
0.00 to 14.00 pH |
2-Wire Transmitter |
|
1/4 DIN panel mount or wall-mount, 3-wire/2-wire selectable, Symmetrical mode of operation |
pH/mV/°C |
0.00 to 14.00 pH |
Monitor |
|
1/4 DIN panel mount or wall mount, 2 set points relays, Alarm with time-delay function |
pH/mV/°C |
0.00 to 14.00 pH |
Limit Control |
|
1/4 DIN panel mount, 2 set points relays |
pH/mV/°C |
-2.00 to 16.00 pH |
Limit Control |
|
1/4 DIN panel mount 2 set points, 1 alarm relay |
pH/mV/°C |
-2.00 to 16.00 pH |
Limit or Proportional Control (Pulse Length or Pulse Frequency) |
|
1/2 DIN wall mount 2 set points, 1 alarm and wash relay |
pH/mV/°C |
-2.00 to 16.00 pH |
Limit, Proportional or Proportional Integral Control (Pulse Length or Pulse Frequency) |
|
1/2 DIN wall mount, Differential measurement, 2 set points, 1 alarm and wash relay |
pH/mV/°C |
-2.00 to 16.00 pH |
Limit, Proportional or Proportional Integral Control (Pulse Length or Pulse Frequency) |
Process Electrodes |
Model
|
pH
Range |
Operating
Temperature |
Temperature
Sensor
|
Potential
Matching Pin |
0 to 14 |
0 to 80 °C / 32 to 176 ºF |
Pt 100 |
Platinum |
|
0 to 14 |
0 to 80 °C / 32 to 176 ºF |
Pt 100 |
Platinum |
|
0 to 14 |
0 to 80 °C / 32 to 176 ºF |
Pt 100 |
Platinum |
|
0 to 14 |
0 to 80 °C / 32 to 176 ºF |
– |
Platinum |
|
0 to 14 |
0 to 110 °C / 32 to 230 ºF high temp. |
– |
– |
|
0 to 14, HF resistant |
0 to 80 °C / 32 to 176 ºF |
– |
– |
|
0 to 14 |
0 to 80 °C / 32 to 176 ºF |
– |
– |
|
0 to 14 |
-5 to 95 °C / 23 to 203 ºF |
NTC 300 |
SS316 |
pH Electrodes (General Glass) |
Model
|
pH
Range |
Temperature
Range
|
Liquid Junction Type
|
Reference
Type |
0 to 13 pH |
0 to 100 °C |
Annular ceramic |
Ag/AgCl refillable |
|
0 to 13 pH |
0 to 100 °C |
Annular ceramic |
Ag/AgCl refillable |
|
0 to 13 pH |
0 to 100 °C |
Annular ceramic |
Ag/AgCl refillable |
|
0 to 13 pH |
0 to 100 °C |
Sleeve |
Ag/AgCl refillable |
|
0 to 14 pH |
5 to 110 °C |
Annular ceramic |
Ag/AgCl sealed |
|
0 to 13 pH |
0 to 100 °C |
Annular ceramic |
Ag/AgCl sealed |
|
pH Electrodes (General Plastic) |
Model
|
pH
Range |
Temperature
Range
|
Liquid Junction Type
|
Reference
Type |
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl refillable |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl refillable |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
|
pH Electrodes (Specialty Open Pore) |
Model
|
pH
Range |
Temperature
Range |
Liquid Junction Type
|
Reference
Type |
0 to 14 pH |
0 to 80 °C |
Open Pore |
Ag/AgCl refillable |
|
0 to 14 pH |
0 to 80 °C |
Open Pore |
Polymer-gel sealed |
|
0 to 14 pH |
0 to 60 °C |
Open Pore |
Polymer-gel sealed |
|
2 to 11 pH |
0 to 50 °C |
Open Pore |
Polymer-gel sealed |
|
pH Electrodes (Specialty) |
Model
|
pH
Range |
Temperature
Range |
Liquid Junction Type
|
Reference
Type |
0 to 14 pH |
-5 to 100 °C |
Annular ceramic |
Ag/AgCl refillable |
|
1 to 14 pH |
0 to 50 °C |
Annular ceramic |
Ag/AgCl sealed |
|
1 to 13 pH / 0 to 20 mS/cm |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl refillable |
|
pH/ATC Electrodes (3-in-1) |
Model
|
pH
Range |
Temperature
Range
|
Liquid Junction Type
|
Reference
Type |
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
|
1 to 13 pH |
0 to 80 °C |
Porous HDPE pin |
Ag/AgCl sealed |
..
.
====================================
ORP Meter Series
====================================.
Products > By Parameter > ORP/Redox
Oxidation-Reduction Potential
(ORP) or Redox potential measurements are
used to monitor chemical reactions, to quantify
ion activity, or to determine the oxidizing
or reducing properties of a solution. ORP
is a measurement of the electrical potential
of a redox reaction and serves as a yardstick
to judge how much oxidation or reduction takes
place under existing conditions.
ORP electrodes measure the voltage
across a circuit formed by the measuring metal
half cell and the reference half cell. When
the ORP electrode is placed in the presence
of oxidizing or reducing agents, electrons
are constantly transferred back and forth
on its measuring surface, generating a tiny
voltage. The ORP measurement can be made using
the millivolt mode of a pH meter.
Major areas of usage include
the treatment of industrial wastes, study
of biological systems, oxidation of cyanide,
bleaching of pulp, manufacture of bleach and
reduction of chromate wastes. The measurement
of ORP is also useful in pool water treatment
as an indication of sanitation in relation
to free chlorine parameter.
Eutech offers a wide range of
ORP meters that measure both pH and ORP values
in various educational, laboratory and industrial
applications. These include ORPTestr™10 pocket
tester, portable
meters CyberScan Series pH 300, pH 310, pH 11 and pH 110, EcoScan pH 6 and the CyberScan
bench meter series 510, 1100, 2100, 1500 and the colour touchscreen research-grade series 6000.
meters CyberScan Series pH 300, pH 310, pH 11 and pH 110, EcoScan pH 6 and the CyberScan
bench meter series 510, 1100, 2100, 1500 and the colour touchscreen research-grade series 6000.
Browse by product type:
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Electrodes
• Laboratory Electrodes
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Electrodes
• Laboratory Electrodes
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Platinium ring electrode |
mV |
-999 to +1000 mV |
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical pH, ORP measurement |
pH/mV/°C |
0.00 to 14.00 pH |
No |
|
Economical pH, ORP measurement |
pH/mV/°C |
0.00 to 14.00 pH |
No |
Standard Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Standard Portable |
pH/mV/°C |
-2.00 to 16.00 pH |
50 data sets |
|
Expanded memory, RS232 output |
pH/mV/°C/°F |
-2.00 to 16.00 pH |
100 data sets |
Waterproof Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof Portable |
pH/mV/°C |
-2.00 to 16.00 pH |
16 data sets |
|
Waterproof, GLP |
pH/mV/°C/°F |
-2.00 to 16.00 pH |
50 data sets |
Standard Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Dual display standard bench |
pH/mV/°C |
0.00 to 14.00 pH |
50 data sets |
Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Back-lit dual- display |
pH/mV/°C/°F |
-1.000 to 14.000 pH |
100 data sets |
|
Back-lit dual- display Ion concentration measurement |
pH/mV/Ion/°C/°F |
-1.000 to 14.000 pH |
100 data sets |
Premium Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Extensive display |
pH/mV/°C/°F |
-1.999 to 19.999 pH |
100 data sets |
|
Windows® CE-driven single channel colour touchscreen (with pH FET) |
pH/mV/ °C/°F |
-2.000 to 20.000 pH |
10,000 data sets |
|
Windows® CE-driven single channel colour touchscreen (with pH FET) |
pH/mV/Ion/ °C/°F |
-2.000 to 20.000 pH |
10,000 data sets |
Process Electrodes |
Model
|
ORP
Range |
Operating
Temperature |
Pressure
Tolerance
|
Potential
Matching Pin |
±1000 mV |
0 to 80 °C / 32 to 176 ºF |
6 bar (87 psi) |
Platinum |
|
±1000 mV |
0 to 80 °C / 32 to 176 ºF |
6 bar (87 psi) |
Platinum |
|
±1000 mV |
-5 to 95 °C / 23 to 203 ºF |
6.9 bar (100 psi) |
SS316 |
|
Laboratory Electrodes |
Model
|
ORP
Range |
Temperature
Range |
Sensor
Type |
Reference
Type |
-1000 to 1000 mV |
0 to 80 °C |
Platinum pin |
Ag/AgCl sealed |
|
-1000 to 1000 mV |
0 to 80 °C |
Platinum pin |
Ag/AgCl sealed |
|
-1000 to 1000 mV |
0 to 80 °C |
Platinum pin |
Ag/AgCl refillable |
|
-1000 to 1000 mV |
0 to 80 °C |
Platinum pin |
Ag/AgCl refillable |
|
-1000 to 1000 mV |
0 to 100 °C |
Platinum band |
Ag/AgCl refillable |
====================================
Ion Meter Series
====================================.
Products > By Parameter > Ion
Eutech offers a wide selection
of Ion Selective Electrodes (ISE) and meters
for the measurement of ammonia, bromide, cadmium,
calcium, carbon dioxide, carbonate, chloride,
copper, cyanide, fluoride, iodide, lead, nitrate,
potassium, silver, sulfide and sodium.
The ISE functions in the same
principle as the pH electrode. The pH electrode
is the most commonly used ISE that measures
the activity of hydrogen activity in a solution.ISE
responds to ionic activity or
concentration in a liquid because of the characteristics of the electrode’s sensing membrane. Ideally, the ISE develops an electrical potential which is proportional to the activity or concentration of the ion for which the membrane is selective. For example, the fluoride electrode can be used to directly sense fluoride ion in drinking water.
concentration in a liquid because of the characteristics of the electrode’s sensing membrane. Ideally, the ISE develops an electrical potential which is proportional to the activity or concentration of the ion for which the membrane is selective. For example, the fluoride electrode can be used to directly sense fluoride ion in drinking water.
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical Ion measurement |
Ion/pH/mV/°C |
0.01 - 0.99/ 1.0 - 199.9/ 200 - 1999 ppm |
No |
|
Economical Ion measurement |
Ion/pH/mV/°C |
0.01 - 0.99/ 1.0 - 199.9/ 200 - 1999 ppm |
No |
Economy / Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Large LCD with dual display economy bench |
pH/Ion/ mV-redox ORP/ ºC/ºF |
0.00 to 14.00 pH |
100 data sets |
|
Graphic LCD with backlight & extensive display |
pH/Ion/mV/ °C/°F |
-2.000 to 20.000 pH |
500 data sets |
|
Dual display Ion readout |
Ion/pH/mV/°C |
0.01 to 1999 ppm |
50 data sets |
|
Back-lit dual- display Ion concentration measurement |
pH/m |
====================================
Conductivity Meter Series
====================================
Products > By Parameter > Conductivity
Electrical Conductivity
(EC) meters measure the capacity of ions in
an aqueous solution to carry electrical current.
As the ranges in aqueous solutions are usually
small, the basic units of measurements are
milliSiemens/cm (mS/cm) and microSiemens/cm
(µS/cm).
Conductivity is used widely to determine the level of impurities in water supplies for domestic consumption as well as industrial use. Industries that employ this method include the chemical, semi-conductor, power generation, hospitals, textile, iron and steel, food and beverage, mining,
electroplating, pulp and paper, petroleum and marine industries.
Specific applications include chemical streams, demineraliser output, reverse osmosis, stream boilers, condensate return, waste streams, boiler blowdown, cooling towers, desalinisation, laboratory analysis, fruit peeling and salinity level detection in oceanography.
Conductivity is used widely to determine the level of impurities in water supplies for domestic consumption as well as industrial use. Industries that employ this method include the chemical, semi-conductor, power generation, hospitals, textile, iron and steel, food and beverage, mining,
electroplating, pulp and paper, petroleum and marine industries.
Specific applications include chemical streams, demineraliser output, reverse osmosis, stream boilers, condensate return, waste streams, boiler blowdown, cooling towers, desalinisation, laboratory analysis, fruit peeling and salinity level detection in oceanography.
Some applications
require the measurement of Total Dissolved
Solids (TDS) in mg/L, parts per million (ppm)
or parts per thousand (ppt). The TDS concentration
can be obtained by multiplying the conductivity
value with a factor which is empirically determined.
The total TDS is a mass estimate and is dependent
on the mix of chemical species as well as
the concentration while Conductivity is only
dependent on the concentration of chemical
species.
Eutech offers
a wide range of conductivity meters for these
various applications.
Browse by product type:
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof Pocket Tester Large Dual Display |
Conductivity |
.. to 200.0 µS/cm .. to 2000 µS/cm .. to 20.00 mS/cm |
No |
|
Waterproof Pocket Tester Large Dual Display |
Conductivity |
.. to 2000 µS/cm .. to 20.00 mS/cm |
No |
|
Waterproof Pocket Tester Single Display |
Conductivity |
.. to 19.90 mS/cm |
No |
|
Waterproof Pocket Tester Single Display |
Conductivity |
.. to 1990 µS/cm |
No |
|
Waterproof Economy Pocket Tester Single Display |
Conductivity |
0 to 19.90 mS/cm |
No |
|
Waterproof Economy Pocket Tester Single Display |
Conductivity |
0 to 1990 µS/cm |
No |
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical conductivity measurement |
Conductivity/ºC/ºF |
0.00 - 19.99 µS/cm 20.00 - 199.9 µS/cm 200.0 - 1999 µS/cm 2.00 - 19.99 mS/cm 20.0 - 200.0 mS/cm |
No |
|
Economical conductivity measurement |
Conductivity/ °C |
0 to 19.99 µS/cm, 20.0 to 199.9 µS/cm, 200 to 1999 µS/cm, 2.00 to 19.99 mS/cm, 20.0 to 199.9 mS/cm |
No |
|
Economical conductivity measurement |
Conductivity/ °C |
.. to 199.9 mS/cm |
No |
Standard Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Standard Handheld |
Conductivity/ TDS/°C |
.. to 199.9 mS/cm |
50 data sets |
|
Expanded memory memory, RS232 output |
Conductivity/ TDS/°C/°F |
.. to 199.9 mS/cm |
100 data sets |
Waterproof Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof Handheld |
Conductivity/ TDS/Salinity/ Resistivity/ °C/°F |
.. to 500.0 mS |
500 data sets |
|
Waterproof Handheld |
Conductivity/ TDS /°C/°F |
.. to 200.0 mS |
500 data sets |
|
Waterproof Handheld |
Conductivity/ TDS/Salinity/ °C/°F |
0 to 200 mS |
500 data sets |
|
Waterproof GLP |
Conductivity/ TDS/°C/°F |
.. to 199.9 mS |
50 data sets |
|
Waterproof GLP |
Conductivity/ °C/°F |
.. to 199.9 mS |
50 data sets |
|
Waterproof GLP |
Conductivity/ TDS/°C/°F |
.. to 199.9 mS |
50 data sets |
|
Waterproof Handheld |
Conductivity/ TDS/°C/°F |
0 to 200 mS |
150 data sets |
Economy / Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Large LCD with dual display economy meter |
Conductivity/ TDS/ºC/ºF |
.. µS to 200.0 mS |
100 data sets |
|
Economical, high performance |
Conductivity/ TDS/°C/°F |
.. to 199.9 mS/cm |
50 data sets |
|
Graphic LCD with backlight & extensive display |
Conductivity/ TDS/Salinity/ Resistivity/ °C/°F |
0.050 µS to 500.0 mS |
500 data sets |
Premium Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
0.001 resolution, optimum performance |
Conductivity/ TDS/Resistivity/ °C/°F |
.. to 500 mS/cm |
100 data sets |
|
Windows® CE-driven single channel colour touchscreen |
Conductivity/ Resistivity/TDS/ Salinity |
.. to 500 mS/cm |
10,000 data sets |
Process Instruments |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Controller
Functions
|
1/8 DIN panel mount, 2 set points relays, Easy set point adjustment and direct CAL |
Conductivity/ °C |
.. to 200 mS/cm |
Limit Control |
|
1/8 DIN panel mount, 2 set points relays, Password protection for set point adjustment and calibration |
Conductivity/ °C |
.. to 200 mS/cm |
Limit Control |
|
2-wire transmitter, panel mount or wall mount, 'out-of-range' and 'hold' indicators |
Conductivity/ °C |
.. to 200 mS/cm |
2-Wire Transmitter |
|
1/4 DIN panel mount or wall-mount, 3-wire/2-wire selectable, Symmetrical mode of operation |
Conductivity/ °C |
.. to 200 mS/cm |
Monitor |
|
1/4 DIN panel mount or wall mount, 2 set points relays, Alarm with time-delay function |
Conductivity/ °C |
.. to 200 mS/cm |
Limit Control |
|
1/4 DIN panel mount 2 set points, 1 alarm relay |
Conductivity/ °C |
.. to 199.9 mS/cm |
Limit or Proportional Control (Pulse Length or Pulse Frequency) |
|
1/2 DIN wall mount 2 set points, 1 alarm and wash relay |
Conductivity/ °C |
.. to 1000 mS/cm |
Limit, Proportional or Proportional Integral Control (Pulse Length or Pulse Frequency) |
Process Electrodes |
Model
|
Conductivity
Range |
Operating
Temperature |
Cell
Constant, K |
Pressure Rating
at 25 ºC |
Up to 500 mS/cm |
-5 to 100 °C / 23 to 212 ºF |
0.3, 4-cell |
6 bar (87 psi) |
|
0.055 to 20 µS/cm |
-5 to 50 °C / 23 to 122 ºF |
0.01, 2-cell |
3.4 bar (50 psi) |
|
0.055 to 20 µS/cm |
-5 to 80 °C / 23 to 176 ºF |
0.01, 2-cell |
5.5 bar (80 psi) |
|
0.055 to 20 µS/cm |
-5 to 50 °C / 23 to 122 ºF |
0.01, 2-cell |
3.4 bar (50 psi) |
|
0.055 to 20 µS/cm |
-5 to 80 °C / 23 to 176 ºF |
0.01, 2-cell |
5.5 bar (80 psi) |
|
0.5 to 200 µS/cm |
-5 to 50 °C / 23 to 122 ºF |
0.1, 2-cell |
3.4 bar (50 psi) |
|
0.5 to 200 µS/cm |
-5 to 150 °C / 23 to 302 ºF |
0.1, 2-cell |
6.8 bar (100 psi) |
|
0.01 to 100 mS/cm |
-5 to 50 °C / 23 to 122 ºF |
1.0, 2-cell |
3.4 bar (50 psi) |
|
0.01 to 200 mS/cm |
-5 to 120 °C / 23 to 248 ºF |
1.0, 2-cell |
6.8 bar (100 psi) |
|
0.01 to 2 mS/cm |
-5 to 50 °C / 23 to 122 ºF |
1.0, 2-cell |
1 bar (14 psi) |
|
0.01 to 200 mS/cm |
-5 to 120 °C / 23 to 248 ºF |
1.0, 2-cell |
6.8 bar (100 psi) |
|
Laboratory Electrodes |
Model
|
Conductivity
Range
|
Temperature
Range
|
Sensor
Type |
Reference
Type |
0 to 150 mS |
0 to 80 °C |
Platinum pin |
Ag/AgCl sealed |
|
0 to 150 mS |
0 to 80 °C |
Platinum pin |
Ag/AgCl sealed |
|
0 to 150 mS |
0 to 80 °C |
Platinum pin |
Ag/AgCl refillable |
|
0 to 500 mS |
0 to 70 °C |
Platinum pin |
Ag/AgCl refillable |
|
0 to 150 mS |
0 to 80 °C |
Platinum band |
Ag/AgCl refillable |
|
0 to 150 mS |
0 to 80 °C |
Platinum band |
Ag/AgCl refillable |
|
< 200 µS |
0 to 80 °C |
Platinum pin |
Ag/AgCl refillable |
|
< 1 mS |
0 to 80 °C |
Platinum pin |
Ag/AgCl refillable |
|
0 to 350 mS |
0 to 100 °C* |
Platinum band |
Ag/AgCl refillable |
|
0 to 350 mS |
0 to 100 °C* |
Platinum band |
Ag/AgCl refillable |
TDS Meter Series
====================================
Products > By Parameter > Total Dissolved Solids
The total TDS is a mass estimate
and is dependent on the mix of chemical species
as well as the concentration while conductivity
is only dependent on the concentration of
chemical species. Some applications require
the measurement of Total Dissolved Solids
(TDS) in mg/L, parts per million (ppm) or
parts per thousand (ppt). The TDS concentration
can be obtained by multiplying the conductivity
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr™ series, EcoScan TDS 6, CyberScan Standard Portables
CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory
research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON
6000.
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr™ series, EcoScan TDS 6, CyberScan Standard Portables
CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory
research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON
6000.
Browse by product type:
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handheld
• Bench Meters
• Process Instruments
• Pocket-Sized Testers
• Economy Handhelds
• Standard Handhelds
• Waterproof Handheld
• Bench Meters
• Process Instruments
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof Pocket Tester Large Dual Display |
TDS |
.. to 100.0 ppm .. to 1000 ppm .. to 10.00 ppt (depending on TDS factor) |
No |
|
Waterproof Pocket Tester Large Dual Display |
TDS |
.. to 1000 ppm .. to 10.00 ppt |
No |
|
Waterproof Pocket Tester Single Display |
TDS |
.. to 10.00 ppt |
No |
|
Waterproof Pocket Tester Single Display |
TDS |
.. to 1990 ppm |
No |
|
Waterproof Economy Pocket Tester Single Display |
TDS |
0 to 10.00 ppt |
No |
|
Waterproof Economy Pocket Tester Single Display |
TDS |
0 to 1990 ppm |
No |
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical TDS measurement |
TDS/ºC/ºF |
0.00 - 9.99 ppm 10.0 - 99.9 ppm 100 - 999 ppm 1.00 - 9.99 ppt 10.0 - 99.9 ppt |
No |
|
Economical TDS measurement |
TDS/°C |
0 to 9.99 ppm, 10.0 to 99.9 ppm, 100 to 999 ppm, 1.00 to 9.99 ppt, 10.0 to 99.9 ppt |
No |
|
Economical TDS measurement |
TDS/°C |
.. to 200 ppt |
No |
Standard Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Standard handheld |
Conductivity/ TDS/°C |
.. to 200 ppt |
50 data sets |
|
Expanded memory memory, RS232 output |
Conductivity/ TDS/°C/°F |
.. to 200 ppt |
100 data sets |
Waterproof Handheld |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof GLP |
Conductivity/ TDS/°C/°F |
.. to 200 ppt |
50 data sets |
Standard Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical, high performance |
Conductivity/ TDS/°C/°F |
.. to 200 ppt |
50 data sets |
Premium Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
0.001 resolution, optimum performance |
Conductivity/ TDS/Resistivity/ °C/°F |
.. to 99,999 ppm |
100 data sets |
|
Windows® CE-driven single channel colour touchscreen |
Conductivity/ Resistivity/TDS/ Salinity |
Up to 500 ppt |
10,000 data sets |
Process Instruments |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Controller
Functions
|
1/8 DIN panel mount, 2 set points relays, Easy set point adjustment and direct CAL |
TDS/°C |
.. to 200 ppt |
Limit Control |
|
1/8 DIN panel mount, 2 set points relays, Password protection for set point adjustment and calibration |
TDS/°C |
.. to 200 ppt |
Limit Control |
Salinity Meter Series
====================================
Products > By Parameter > Salinity
Salinity measurements are common
in industries like agriculture, aquaculture,
hydroponics, food, pools and spas where it
is necessary to monitor the salt level constantly.
The values are usually read in parts per thousand
(ppt) or % (1 ppt = 1 gram per litre).
The Eutech Salinity Pocket Testers SaltTestr™ series and EcoScan Salt 6 are specially developed to provide direct readings in these applications.
The Eutech Salinity Pocket Testers SaltTestr™ series and EcoScan Salt 6 are specially developed to provide direct readings in these applications.
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof pocket-sized tester |
SALT |
0 to 10.00 ppt |
Yes |
|
Waterproof Economy Pocket Tester |
Salinity |
0 to 10.00 ppt |
No |
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Palmtop for high accuracy and wide range salinity measurements |
SALT/ºC/ºF |
1.0 to 50.0 ppt / 0.1 to 5.00 % |
No |
|
Palmtop for high accuracy and wide range salinity measurements |
SALT/°C |
1.0 to 50.0 ppt / 0.1 to 5.00 % |
No |
|
Palmtop for high accuracy and wide range salinity measurements |
SALT/°C |
1.0 to 50.0 ppt / 0.1 to 5.00 % |
No |
====================================
DO Meter Series
====================================
Products > By Parameter > Dissolved Oxygen
DO stands for Dissolved Oxygen,
which is the measure of amount of gaseous
oxygen dissolved in a solution. In theory,
the amount of DO in a solution is dependent
on 3 factors, namely temperature, salinity
and atmospheric pressure. The measurement
of DO requires a special DO electrode that
is made up of an anode, a cathode, electrolyte
solution and a gas permeable membrane.
Browse by product type:
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
• Economy Handhelds
• Standard Handhelds
• Waterproof Handhelds
• Bench Meters
• Process Instruments
• Process Electrodes
• Laboratory Electrodes
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Economical DO meter |
DO / °C |
0.00 to 19.99 mg/l or ppm |
No |
|
Economical DO Meter |
DO / °C |
0.00 to 19.99 mg/l or ppm |
No |
Standard Handhelds |
Model
|
Meter
Highlights
|
Parameter
|
Range
|
Memory
|
Standard Portable |
DO / °C / °F |
0.00 to 19.99 mg/l or ppm |
100 data sets |
Waterproof Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Mega-Memory, Waterproof, Back-lit Multi-data Display |
DO/°C/°F |
0.00 to 90 mg/L or ppm; 0 to 600% saturation of oxygen |
500 data sets |
|
Waterproof Handheld |
DO/°C/°F |
0 to 20 ppm/mg/L; 0 to 200 % |
500 data sets |
|
Waterproof, Back-lit Display |
DO/°C /°F |
0.00 to 19.99 mg/l or ppm |
50 data sets |
Economy / Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Large LCD with dual display economy meter |
Dissolved Oxygen/ºC/ºF |
0 to 30 mg/L |
100 data sets |
|
Graphic LCD with backlight & extensive display |
Dissolved Oxygen/ BOD/°C/°F |
0 to 19.99 mg/L ; 50.0 mg/L |
500 data sets |
|
Self-stirring BOD Probe Compatible |
DO/°C/°F |
0 to 60 mg/l or ppm |
100 data sets |
|
Windows® CE-driven, BOD,OUR and SOUR Measurement, Colour Touchscreen |
DO/BOD/OUR/ SOUR/°C/°F |
0 to 60 mg/l or ppm |
10,000 data sets |
Process Instruments |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Controller
Functions
|
1/4 DIN LCD Transmitter |
DO/°C/°F |
0.00 to 19.99 mg/l or 0.00 to 19.99 ppm |
||
1/4 DIN Panel Mount 2 Set Points, 1 Alarm Relay |
DO/°C/°F |
0.00 to 20.00 mg/I or 0.0 to 200.0 % Saturation |
Limit or Proportional Control (Pulse Length or Pulse Frequency) |
|
1/2 DIN Wall Mount 2 Set Points, 1 Alarm and Wash Relay |
DO/°C/°F |
0.00 to 25.00 mg/l or 0.0 to 300.0% Saturation |
Limit, Proportional or Proportional Integral Control (Pulse Length or Pulse Frequency) |
Process Electrodes |
Model
|
Dissolved
Oxygen Range |
Operating
Temperature |
Pressure
Rating |
Type
|
0.50 to 20 ppm |
0 to 50 ºC / 32 to 122 ºF |
6 bar (87 psi) |
Galvanic |
|
0.03 to 20 ppm |
0 to 50 ºC / 32 to 122 ºF |
6 bar (87 psi) |
Galvanic |
|
0.04 ppm to saturation |
0 to 60 ºC / 32 to 140 ºF |
4 bar (58 psi) |
Amperometric
|
|
0.01 ppm to saturation |
0 to 130 ºC / 32 to 248ºF |
4 bar (58 psi) |
Amperometric |
|
Laboratory Electrodes |
Model
|
DO
Range |
Temperature
Range
|
Sensor
Type |
Minimum
Sample Flow |
0 to 20 mg/L |
0 to 50 °C |
Galvanic |
2 inch / sec |
|
0 to 20 mg/L |
0 to 50 °C |
Galvanic |
2 inch / sec |
|
0 to 20 mg/L |
0 to 50 °C |
Galvanic |
2 inch / sec |
|
0 to 20 mg/L |
15 to 35 °C |
BOD amperometric |
Self-stirring |
|
0 to 20 mg/L |
0 to 50 °C |
Galvanic |
2 inch / sec |
====================================
Colori Meter Series
====================================
Products > By Parameter > Colorimetry
Colorimetry is defined as the
measurement of a parameter whose concentration
is proportional (directly or inversely related)
to color intensity after the addition of known
volume of reagent(s). Different chemical substances
absorb different and varying visual light
frequencies. Since the absorbance of a substance
is proportional to its concentration i.e.,
a more concentrated solution gives a higher
absorbance reading, therefore the concentration
of a known solute can be measured using a
colorimeter.
colorimeter.
Eutech’s latest range of portable
waterproof colorimeters measure Chlorine (Free
and Total), Cyanuric Acid, pH, Chlorine Dioxide,
Bromine and Ozone. The applications include
water analysis in swimming pools, spas, public
utilities, industrial wastewater plants, municipal
water, treated water, water conditioning systems
and paper and pulp mills.
The effectiveness of the disinfectants
used depends on your system’s overall water
chemistry, and not just on the disinfectants’
concentrations alone. Click
here for a brief overview on the measurement
of each parameter.
Waterproof Handhelds |
Model
|
Meter
Highlights
|
Parameter
|
Range
|
Photometric |
Chlorine, Free and Total / Cyanuric Acid / pH |
0 to 1.99 ppm/ 2.0 to 6.0 ppm/ 5.9 to 8.2 pH |
|
Photometric |
Chlorine, Free and Total / pH |
0 to 1.99 ppm/ 5.9 to 8.2 pH |
|
Photometric |
Chlorine, Free and Total |
0 to 1.99 ppm |
|
Photometric |
Ozone |
0 to 1.39 ppm 1.4 to 4.1 ppm |
|
Photometric |
Bromine |
0 to 4.49 ppm 4.5 to 13.5 ppm |
|
Photometric |
Chlorine Dioxide |
0 to 3.79 ppm 3.8 to 11.4 ppm |
|
Photometric |
Cyanuric Acid |
5 to 90 ppm |
|
Photometric |
pH |
5.9 to 8.2 pH |
====================================
Turbidity Meter Series
====================================
Products > By Parameter > Turbidity
Turbidity refers to the concentration
of undissolved, suspended particles present
in a liquid measured in
Nephelometric Turbidity Units (NTU). It is important to note that turbidity is a measure of sample clarity and not colour. Water with cloudy or opaque appearance will have high turbidity, while water that is clear or translucent will have low turbidity. High turbidity value is caused by particles such as silt, clay, microorganisms, and organic matter. By definition, turbidity is not a direct measure of these particles
but rather a measure of how these particles scatter light.
Nephelometric Turbidity Units (NTU). It is important to note that turbidity is a measure of sample clarity and not colour. Water with cloudy or opaque appearance will have high turbidity, while water that is clear or translucent will have low turbidity. High turbidity value is caused by particles such as silt, clay, microorganisms, and organic matter. By definition, turbidity is not a direct measure of these particles
but rather a measure of how these particles scatter light.
Turbidity is a very complex analytical
measurement which can be affected by many
factors. Some are inherent in the instrument’s
design such as angle of detection, light beam
aperture, incident beam wavelength and colour
sensitivity of the photocell. However, there
are other factors such as stray light, air
bubbles and care of vial, which can be prevented
through proper care of equipment and accessories.
The Eutech CyberScan TB 1000
Turbidimeter meets the performance criteria
specified by US EPA
method 180.1 for NTU measurement. In addition, the infrared light source models meet the ISO
7027 standards of measurement. The Eutech Waterproof Portable TN 100 Turbidimeter
designed for testing on-the-go features laboratory accuracy and excellent repeatability with US EPA
approved non-formazin standards and is ISO 7027 compliant.
method 180.1 for NTU measurement. In addition, the infrared light source models meet the ISO
7027 standards of measurement. The Eutech Waterproof Portable TN 100 Turbidimeter
designed for testing on-the-go features laboratory accuracy and excellent repeatability with US EPA
approved non-formazin standards and is ISO 7027 compliant.
Waterproof Handheld |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Light weight, IP67 Waterproof handheld meter |
Turbidity |
0 to 2000 NTU |
||
Light weight, IP67 Waterproof handheld meter |
Turbidity |
0 to 1000 NTU |
Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Turbidity bench, GLP, RS232 |
Turbidity |
0 to 1000 NTU |
====================================
Temperature Meter Series
====================================
Products > By Parameter > Temperature
Browse by product type:• Economy Handhelds
• Standard Handhelds
• Laboratory Electrodes
Economy Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
100K Thermistor Temperature Probe |
°C / °F |
-40.0 to 125.0 °C -40.0 to 257 °F |
||
3 wire RTD Pt100 Temperature Probe |
°C / °F |
-200.0 to 850.0 °C -328.0 to 1562 °F |
||
Type J, K & T Thermocouple |
°C / °F |
Type J -200 to 1000 °C (-328 to 1832 °F) Type K -250 to 1372 °C (-418 to 2502 °F) Type T -250 to 400 °C (-418 to 752 °F) |
Thermo Scientific Temp Series Temperature Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Single-Input Thermocouple |
°C / °F |
Type J -210 °C to 1200 °C (-346 °F to 2192 °F) Type K -250 °C to 1372 °C (-418 °F to 2501 °F) Type T -250 °C to 400 °C (-418 °F to 752 °F) |
– |
|
Single-Input Precision RTD |
°C / °F |
-200.0 °C to 850.0 °C (-392 °F to 1562 °F) |
– |
|
Dual-Input Thermocouples |
°C / °F |
Type R 0 °C to 1768 °C (32 °F to 3214 °F) Type S 0 °C to 1768 °C (32 °F to 3214 °F) Type N -250 °C to 1300 °C (-418 °F to 2372 °F) Type B 200 °C to 1800 °C (392 °F to 3272 °F) |
2000 |
|
Precision RTD Datalogging Thermometer |
°C / °F |
-201°C to 1210 °C (-330 °F to 2210 °F) |
2000 data sets |
ATC Probes |
Model
|
Temperature
Range
|
Material
|
0 to 100 °C |
Stainless steel 304 |
|
0 to 100 °C |
Stainless steel 304 |
|
0 to 100 °C |
Stainless steel 304 |
|
0 to 100 °C |
Stainless steel 304 |
|
0 to 100 °C |
Stainless steel 304 |
|
0 to 100 °C |
Stainless steel 304 |
|
Temperature Probes |
Model
|
Temperature
Range
|
Meter
|
0 to 125 °C |
Thermistor |
|
-50 to 150 °C |
RTD |
|
-50 to 700 °C |
Type J |
|
-50 to 700 °C |
Type K |
|
-50 to 700 °C |
Type J |
|
-50 to 700 °C |
Type K |
====================================
Multi Parameter Series
====================================
Products > By Parameter > Multi-Parameter
One cost-effective and convenient
way to measure multiple parameters without
the need to purchase many different meters
is to make use of a multi-parameter meter.
Most of these meters are able to measure 2
or more parameters. The models featured here
measure pH, conductivity and dissolved oxygen.
Pocket-Sized Testers |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof pocket-sized tester |
pH/Conductivity/ TDS/Salinity/ °C/°F |
0.00 to 14.00 pH |
No |
|
Waterproof pocket-sized tester |
pH/Conductivity/ °C/°F |
0.0 to 14.0 pH |
No |
|
Waterproof pocket-sized tester |
pH/TDS/ °C/°F |
0.0 to 14.0 pH |
No |
Waterproof Handhelds |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Waterproof, simultaneous measurement & display of 4 parameters, wireless data transfer |
pH / mV / Ion / Conductivity / TDS / Salinity / DO / °C / °F |
-2.000 to 16.000 pH |
500 data sets |
|
Waterproof, simultaneous measurement & display of 3 parameters, wireless data transfer |
pH / mV / Ion / Conductivity / TDS / Salinity / °C / °F |
-2.000 to 16.000 pH |
500 data sets |
|
Waterproof, simultaneous measurement & display of 3 parameters, wireless data transfer |
pH / mV / Ion / DO / °C / °F |
-2.000 to 16.000 pH |
500 data sets |
|
Waterproof, simultaneous measurement & display of 3 parameters, wireless data transfer |
Conductivity / TDS / Salinity / DO / °C / °F |
-2.000 to 16.000 pH |
500 data sets |
|
Waterproof, Single pH/Con probe or separate pH & conductivity probes |
pH/mV/ Conductivity/ TDS/Salinity/ºC/ºF |
-2.00 to 16.00 pH |
500 data sets |
|
Waterproof, Maintenance free optical probe |
pH/mV/ DO/°C/°F |
-2.00 to 16.00 pH |
500 data sets |
|
Waterproof, Speciality probe compatible |
pH / °C / °F / Conductivity / TDS |
-2.00 to 16.00 pH |
||
Waterproof Portable |
pH / °C / DO |
-2.00 to 16.00 pH |
||
Waterproof, Combined multi- submersible probe |
pH / °C / Conductivity |
0.00 to 14.00 pH |
Economy / Deluxe Bench |
Model
|
Meter
Highlights |
Parameter
|
Range
|
Memory
|
Large LCD with dual display economy meter |
pH/ORP/ Conductivity/ TDS/Resistivity/ ºC/ºF |
0.00 to 14.00 pH |
100 data sets |
|
Bench multi- parameter |
pH / °C / °F / Conductivity / TDS |
-2.00 to 16.00 pH |
||
Graphic LCD with backlight & extensive display |
pH/mV/Ion/ Conductivity/ TDS/Salinity/ Resistivity/ °C/°F |
-2.000 to 20.000 pH |
500 data sets |
.
.
.
.
.
.
.
.
.
.