Finding odor source at factories, incinerator plants, or effluent treatment facilities etc.
Evaluation for deodorizing at hospitals or nursing homes etc.
For putrid odor such as ammonia.
TVOC measurement for monitoring IAQ condition.
1.Portable Odor level Indicator
Type : XP- 329 III R
Brand : Cosmos - Japan
Specification :
- Substance Measured : Various Odor Component
- Detection Principle : Indium oxide based sensitivy hpt wire semiconductor sensor
- Sampling Method : Extractive " Extractive Flow : 40 + / - 150ml/ min
- Display : LCD digitral indication ( 64x128 dots matrix ) ( Measurement Value, Measurement mode, Operating conditions. remaining battery level, data memory bar indicator for sensor out put and comunication channel etc )
- Measurement Mode : Monitoring Mode, Batch Mode
- Detection Range : Level Indication 0-2000 ( in case of zero - based setting at the 2nd dot from the left in the sensor out put bar graph )
- Repeatability : Measurement Value + / -5% + / -1 Digit + 1 Level Indication
- Response time : 20 s less ( 90% Response ) By Calibrated Odor
- External Out Put : Analog output level indication 0000-2000 coresponding to DC 0-200 mV ( 0.1mV as contrasted with indication 1) ( Except approx 204.8mV in case of over Level ) , Digital input/ output. RS-232C output indicatedvalue ( ASCII Code ) ( Except in case of Over Level, output { * * * * } )
- External Output Terminal : DIN connector for both analog output and digital input/ output
- Operating Temperature & Humidity : Temperature 0-40 deg , Humidity : 10-80% RH ( non-condensing )
- Dimensions WxHxD : 84 x 275 x 40 mm ( Excluding protrusions )
- Weight : Approx 640 gr ( Including Batteries )
- Power Source : 4 x AA Alkaline dry cells or AC adaptor
- Battery Life : Up to 8 hours by alkaline cells, Low battery Alarm funstions
- Standart Accessories : Activated carbon Filter, Drain Filter, Sample Draw attachment, tube in take, AC Adaptor, carryng case, output connector, communication pack ( CD ) , 4xAA Alkaline Dry Cells, Teflon tube ( 1m) , 2 x Activatedcarbons, 2 x filter elements ( 10 pcs ) , instruction manual, test report
1.Portable Odor level Indicator
Type : XP- 329 III R
Brand : Cosmos - Japan
Specification :
- Substance Measured : Various Odor Component
- Detection Principle : Indium oxide based sensitivy hpt wire semiconductor sensor
- Sampling Method : Extractive " Extractive Flow : 40 + / - 150ml/ min
- Display : LCD digitral indication ( 64x128 dots matrix ) ( Measurement Value, Measurement mode, Operating conditions. remaining battery level, data memory bar indicator for sensor out put and comunication channel etc )
- Measurement Mode : Monitoring Mode, Batch Mode
- Detection Range : Level Indication 0-2000 ( in case of zero - based setting at the 2nd dot from the left in the sensor out put bar graph )
- Repeatability : Measurement Value + / -5% + / -1 Digit + 1 Level Indication
- Response time : 20 s less ( 90% Response ) By Calibrated Odor
- External Out Put : Analog output level indication 0000-2000 coresponding to DC 0-200 mV ( 0.1mV as contrasted with indication 1) ( Except approx 204.8mV in case of over Level ) , Digital input/ output. RS-232C output indicatedvalue ( ASCII Code ) ( Except in case of Over Level, output { * * * * } )
- External Output Terminal : DIN connector for both analog output and digital input/ output
- Operating Temperature & Humidity : Temperature 0-40 deg , Humidity : 10-80% RH ( non-condensing )
- Dimensions WxHxD : 84 x 275 x 40 mm ( Excluding protrusions )
- Weight : Approx 640 gr ( Including Batteries )
- Power Source : 4 x AA Alkaline dry cells or AC adaptor
- Battery Life : Up to 8 hours by alkaline cells, Low battery Alarm funstions
- Standart Accessories : Activated carbon Filter, Drain Filter, Sample Draw attachment, tube in take, AC Adaptor, carryng case, output connector, communication pack ( CD ) , 4xAA Alkaline Dry Cells, Teflon tube ( 1m) , 2 x Activatedcarbons, 2 x filter elements ( 10 pcs ) , instruction manual, test report
2.Handheld Odor Meter
Type : OMX-SRM
Product : Shinyei Technology
Specification :
ª Sensor : Two semiconductor gas sensors
ª Detection gas : Ethanol, Acetone, Hydrogen, etc
ª Sampling Method : Continuous sampling with built-in air pump
ª Range : 0, 0-999 µ g/ m3
ª Classification : Class 0~ 90
ª Power supply : Four " AA " alkaline dry batteries/ AC adaptor
ª Memory Capacity : Up to 32, 732 Data
ª Memory Partition : Up to 511 Files
ª Storage Temperature : 0 ^ 40 ( 32-104F) * No Dew Condensation
ª Odor Strength Level : -10 ^ 50 ( 14-122F) * No Dew Condensation
Dimensions : W74 X L167.5 X D35mm approx.
ª Weight : 250g approx. ( Without Batteries)
Accessories : USB Cable, Air Purifying Unit, Activated Carbon, Data Filing Software, 4× AA Size Alkaline Batteries, AC Adaptor
http://www.youtube.com/watch?v=DyASoJr9J78
3. Odor Meter
Type : OMX-ADM
Merk : Shinyei Technology
Specification :
ª Sensor : Two semiconductor gas sensors
ª Detection gas : TVOC ( Tolune) , etc
ª Sampling Method : Continuous sampling with built-in air pump
ª Range : 0-9999 µ g/ m3
ª Classification : Odor Intensity 2.5~ 5.0
ª Power supply : Four " AA " alkaline dry batteries/ AC adaptor
ª Memory Capacity : Up to 32, 732 Data
ª Memory Partition : Up to 511 Files
ª Storage Temperature : 0 ^ 40 ( 32-104F) * No Dew Condensation
ª Odor Strength Level : -10 ^ 50 ( 14-122F) * No Dew Condensation
Dimensions : W74 X L167.5 X D35mm approx.
ª Weight : 250g approx. ( Without Batteries)
Accessories : USB Cable, Air Purifying Unit, Activated Carbon, Data Filing Software, 4× AA Size Alkaline Batteries, AC Adaptor
4. Portable Odor meter / Alat Ukur Kadar Bau Tingkat bau , Fungsi ( Untuk mengukur kadar campuran bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll)
Specification :
ª Parameters
1 Odor : 1~ 100 OU ( Low) : 1~ 300 OU ( High)
2 H2S : 0~ 2 ppm ( Low)
: 0~ 50 ppm ( High)
3 NH3 : 0~ 15 ppm ( Low)
: 0~ 50 ppm ( High)
4 VOC : 0~ 20 ppm ( Low)
: 0~ 80 ppm ( High)
ª Measurement Principle : Reaction of sensor utilizing the
absorption and desorption of
manifold sensor system
ª Accuracy : ± 3% RSD
ª Response Time/ : 1~ 3 minutes selectable /
ª Measurement Method : One time or continuous measurement
ª Operating System : WinCE System
Communication : RS-232 PC Communication
ª ( programs) , Ethernet
ª DATA Storage : SD Card ( 2GB)
ª H x W x D, kg : 80 x 340 x 240, 7kg
Power Supply : AC 180 ~ 250V, 60Hz, 75W,
ª Built-in Battery
Exterior Materia : ABS Resin
Information Order ( pilih sesuai dengan kebutuhan)
1 Main unit
Complex Odor
H2S
Manual Books
Carrying case
2 Main unit
Complex Odor
H2S
NH3
VOCs
Manual Books
Carrying case
5. Hand Held Odor Meter / ALAT UKUR KADAR BAU, Tingkat bau, Fungsi: Untuk mengukur kadar bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll
Specification :
Hand-Held Odor Meter.
Fungsi: Untuk mengukur kadar bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll.
ª Parameters :
1 Odor/ : 1~ 100 OU ( Low)
2 H2S : 0~ 2 ppm ( Low)
: 0~ 50 ppm ( High)
3 NH3 : 0~ 15 ppm ( Low)
: 0~ 50 ppm ( High)
ª Measurement Principle : Reaction of sensor utilizing the
: absorption and desorption of
manifold sensor system
ª Accuracy : ± 5% RSD
ª Response Time/ : 1~ 5 minutes selectable
ª Measurement Method : One time or continuous measurement
ª Operating System : MCU ( Micro Controller Unit) system
ª Communication : RS-232 PC Communication
( Program) , Pocket Printer.
ª DATA Storage : Built-in Memory, capable of storing
over 200 measured data.
ª Size ( H x W x D) : 230 x 120 x 40, 0mm
ª Weight : 0.65kg
ª Power Supply : Exclusive 9V 1.5A Adapter,
Built-in Battery
ª Exterior Material : ABS Resin
6. Ambient ODOR Monitoing ( FUNGSI : Untuk monitoring kadar bau, H2S, NH3 VOC dan Cuaca secara terus menerus ) Tingkat Bau
Specification :
Ambient ODOR Monitoing
Parameters.
1 Odor : 1~ 300 OU ( Ambient)
: 1~ 300 OU ( Stack)
2 H2S : 0~ 2 ppm ( Ambient)
: 0~ 50 ppm ( Stack)
3 NH3 : 0~ 15 ppm ( Ambient)
: 0~ 50 ppm ( Stack)
4 VOCs : 0~ 20 ppm ( Ambient)
: 0~ 80 ppm ( Stack)
Measurement Principle : Reaction of sensor utilizing the
absorption and desorption of
Manifold Sensor System.
ª Accuracy : ± 5% RSD
ª Response Time/ : 1~ 10 minutes selectable /
ª Measurement Method : One time or continuous measurement
ª Operating System : MOU( Micro Controller Unit)
ª Communication : RS-232 PC communication( program)
Wire/ wireless DATA transmit( CDMA,
Zigbee, RF, Ethernet)
ª DATA Storage : SD Card ( 2GB)
ª Size H x W x D, : 670 x 755 x 245
ª Weight : 40 kg
ª Support : 1100 mm
ª Power Supply : AC 110 ~ 250V, 60Hz, 100W
ª Exterior Material : SUS 316( Color pulverulent painting) ,
Waterproof case.
..
.
.
.
.
.
.
.
.
.