HP :
081362449440 / 081310157965
Email
: b081362449440@yahoo.com
Up :
Mr Jonathan
===============================
===============================



1.Portable Odor level Indicator
Type : XP- 329 III R
Brand : Cosmos - Japan
Specification :
- Substance Measured : Various Odor Component
- Detection Principle : Indium oxide based sensitivy hpt wire semiconductor sensor
- Sampling Method : Extractive " Extractive Flow : 40 + / - 150ml/ min
- Display : LCD digitral indication ( 64x128 dots matrix ) ( Measurement Value, Measurement mode, Operating conditions. remaining battery level, data memory bar indicator for sensor out put and comunication channel etc )
- Measurement Mode : Monitoring Mode, Batch Mode
- Detection Range : Level Indication 0-2000 ( in case of zero - based setting at the 2nd dot from the left in the sensor out put bar graph )
- Repeatability : Measurement Value + / -5% + / -1 Digit + 1 Level Indication
- Response time : 20 s less ( 90% Response ) By Calibrated Odor
- External Out Put : Analog output level indication 0000-2000 coresponding to DC 0-200 mV ( 0.1mV as contrasted with indication 1) ( Except approx 204.8mV in case of over Level ) , Digital input/ output. RS-232C output indicatedvalue ( ASCII Code ) ( Except in case of Over Level, output { * * * * } )
- External Output Terminal : DIN connector for both analog output and digital input/ output
- Operating Temperature & Humidity : Temperature 0-40 deg , Humidity : 10-80% RH ( non-condensing )
- Dimensions WxHxD : 84 x 275 x 40 mm ( Excluding protrusions )
- Weight : Approx 640 gr ( Including Batteries )
- Power Source : 4 x AA Alkaline dry cells or AC adaptor
- Battery Life : Up to 8 hours by alkaline cells, Low battery Alarm funstions
- Standart Accessories : Activated carbon Filter, Drain Filter, Sample Draw attachment, tube in take, AC Adaptor, carryng case, output connector, communication pack ( CD ) , 4xAA Alkaline Dry Cells, Teflon tube ( 1m) , 2 x Activatedcarbons, 2 x filter elements ( 10 pcs ) , instruction manual, test report
2.Handheld Odor Meter
Type : OMX-SRM
Product : Shinyei Technology
Specification :
ª Sensor : Two semiconductor gas sensors
ª Detection gas : Ethanol, Acetone, Hydrogen, etc
ª Sampling Method : Continuous sampling with built-in air pump
ª Range : 0, 0-999 µ g/ m3
ª Classification : Class 0~ 90
ª Power supply : Four " AA " alkaline dry batteries/ AC adaptor
ª Memory Capacity : Up to 32, 732 Data
ª Memory Partition : Up to 511 Files
ª Storage Temperature : 0 ^ 40 ( 32-104F) * No Dew Condensation
ª Odor Strength Level : -10 ^ 50 ( 14-122F) * No Dew Condensation
Dimensions : W74 X L167.5 X D35mm approx.
ª Weight : 250g approx. ( Without Batteries)
Accessories : USB Cable, Air Purifying Unit, Activated Carbon, Data Filing Software, 4× AA Size Alkaline Batteries, AC Adaptor
http://www.youtube.com/watch?v=DyASoJr9J78
3. Odor Meter
Type : OMX-ADM
Merk : Shinyei Technology
Specification :
ª Sensor : Two semiconductor gas sensors
ª Detection gas : TVOC ( Tolune) , etc
ª Sampling Method : Continuous sampling with built-in air pump
ª Range : 0-9999 µ g/ m3
ª Classification : Odor Intensity 2.5~ 5.0
ª Power supply : Four " AA " alkaline dry batteries/ AC adaptor
ª Memory Capacity : Up to 32, 732 Data
ª Memory Partition : Up to 511 Files
ª Storage Temperature : 0 ^ 40 ( 32-104F) * No Dew Condensation
ª Odor Strength Level : -10 ^ 50 ( 14-122F) * No Dew Condensation
Dimensions : W74 X L167.5 X D35mm approx.
ª Weight : 250g approx. ( Without Batteries)
Accessories : USB Cable, Air Purifying Unit, Activated Carbon, Data Filing Software, 4× AA Size Alkaline Batteries, AC Adaptor
4. Portable Odor meter / Alat Ukur Kadar Bau Tingkat bau , Fungsi ( Untuk mengukur kadar campuran bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll)
Specification :
ª Parameters
1 Odor : 1~ 100 OU ( Low) : 1~ 300 OU ( High)
2 H2S : 0~ 2 ppm ( Low)
: 0~ 50 ppm ( High)
3 NH3 : 0~ 15 ppm ( Low)
: 0~ 50 ppm ( High)
4 VOC : 0~ 20 ppm ( Low)
: 0~ 80 ppm ( High)
ª Measurement Principle : Reaction of sensor utilizing the
absorption and desorption of
manifold sensor system
ª Accuracy : ± 3% RSD
ª Response Time/ : 1~ 3 minutes selectable /
ª Measurement Method : One time or continuous measurement
ª Operating System : WinCE System
Communication : RS-232 PC Communication
ª ( programs) , Ethernet
ª DATA Storage : SD Card ( 2GB)
ª H x W x D, kg : 80 x 340 x 240, 7kg
Power Supply : AC 180 ~ 250V, 60Hz, 75W,
ª Built-in Battery
Exterior Materia : ABS Resin
Information Order ( pilih sesuai dengan kebutuhan)
1 Main unit
Complex Odor
H2S
Manual Books
Carrying case
2 Main unit
Complex Odor
H2S
NH3
VOCs
Manual Books
Carrying case
5. Hand Held Odor Meter / ALAT UKUR KADAR BAU, Tingkat bau, Fungsi: Untuk mengukur kadar bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll
Specification :
Hand-Held Odor Meter.
Fungsi: Untuk mengukur kadar bau, H2S, NH3 dan VOC pada limbah rumah sakit, limbah industri, Fasilitas umum/ WC dll.
ª Parameters :
1 Odor/ : 1~ 100 OU ( Low)
2 H2S : 0~ 2 ppm ( Low)
: 0~ 50 ppm ( High)
3 NH3 : 0~ 15 ppm ( Low)
: 0~ 50 ppm ( High)
ª Measurement Principle : Reaction of sensor utilizing the
: absorption and desorption of
manifold sensor system
ª Accuracy : ± 5% RSD
ª Response Time/ : 1~ 5 minutes selectable
ª Measurement Method : One time or continuous measurement
ª Operating System : MCU ( Micro Controller Unit) system
ª Communication : RS-232 PC Communication
( Program) , Pocket Printer.
ª DATA Storage : Built-in Memory, capable of storing
over 200 measured data.
ª Size ( H x W x D) : 230 x 120 x 40, 0mm
ª Weight : 0.65kg
ª Power Supply : Exclusive 9V 1.5A Adapter,
Built-in Battery
ª Exterior Material : ABS Resin
6. Ambient ODOR Monitoing ( FUNGSI : Untuk monitoring kadar bau, H2S, NH3 VOC dan Cuaca secara terus menerus ) Tingkat Bau
Specification :
Ambient ODOR Monitoing
Parameters.
1 Odor : 1~ 300 OU ( Ambient)
: 1~ 300 OU ( Stack)
2 H2S : 0~ 2 ppm ( Ambient)
: 0~ 50 ppm ( Stack)
3 NH3 : 0~ 15 ppm ( Ambient)
: 0~ 50 ppm ( Stack)
4 VOCs : 0~ 20 ppm ( Ambient)
: 0~ 80 ppm ( Stack)
Measurement Principle : Reaction of sensor utilizing the
absorption and desorption of
Manifold Sensor System.
ª Accuracy : ± 5% RSD
ª Response Time/ : 1~ 10 minutes selectable /
ª Measurement Method : One time or continuous measurement
ª Operating System : MOU( Micro Controller Unit)
ª Communication : RS-232 PC communication( program)
Wire/ wireless DATA transmit( CDMA,
Zigbee, RF, Ethernet)
ª DATA Storage : SD Card ( 2GB)
ª Size H x W x D, : 670 x 755 x 245
ª Weight : 40 kg
ª Support : 1100 mm
ª Power Supply : AC 110 ~ 250V, 60Hz, 100W
ª Exterior Material : SUS 316( Color pulverulent painting) ,
Waterproof case.
..
.
.
.
.
.
.
.
.
.
Your blog specializing in going over the actual without a doubt contemptuous with on their own released coerces. Your blog aid is usually synchronize towards the fit swift. My partner and i from the weblog exuviate to supply. Clues some sort of numerous pertaining to expressing. harga folding gate
BalasHapus